Simulation of relative temporal resolution of time-resolved MRA sequences

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accelerating time-resolved MRA with multiecho acquisition.

A new four-dimensional magnetic resonance angiography (MRA) technique called contrast-enhanced angiography with multiecho and radial k-space is introduced, which accelerates the acquisition using multiecho while maintaining a high spatial resolution and increasing the signal-to-noise ratio (SNR). An acceleration factor of approximately 2 is achieved without parallel imaging or undersampling by ...

متن کامل

Non Contrast Time-Resolved MRA combining High Resolution Multiple Phase EPISTAR (CINEMA-STAR)

Introduction Detailed information on anatomy and hemodynamics in cerebrovascular disorders such as AVM and Moyamoya disease is mandatory for defined diagnosis and treatment planning [1]. DSA may still be a gold standard for diagnostic modality but is otherwise invasive. Contrast-enhanced dynamic MR angiography (CE-dMRA) is a useful technique but poses a risk associated with contrast agent [2]. ...

متن کامل

An Improvement in Temporal Resolution of Seismic Data Using Logarithmic Time-frequency Transform Method

The improvement in the temporal resolution of seismic data is a critical issue in hydrocarbon exploration. It is important for obtaining more detailed structural and stratigraphic information. Many methods have been introduced to improve the vertical resolution of reflection seismic data. Each method has advantages and disadvantages which are due to the assumptions and theories governing their ...

متن کامل

Time-Resolved Contrast-Enhanced MRA Using Cartesian Techniques

INTRODUCTION The last decade has seen major advances in the performance capabilities of time-resolved contrast-enhanced (CE) magnetic resonance angiography (MRA). Today, for example, it is possible to generate 3D time-resolved image sets with higher spatial resolution, wider anatomic coverage, better temporal fidelity, and improved image quality while using smaller acquisition times than what w...

متن کامل

Nonenhanced Time-resolved Mra Using Inflow Arterial Spin Labeling

Introduction A pulsed arterial spin labeling (ASL) technique is useful for obtaining hemodynamics information as well as tissue perfusion without using contrast materials and there are various methods have proposed [1-4]. In the standard ASL techniques, subtraction between a tag pulse and a control pulse is required to enhance blood vessels while subtracting out the background signals. However,...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Magnetic Resonance in Medicine

سال: 2008

ISSN: 0740-3194,1522-2594

DOI: 10.1002/mrm.21658