Simulation and design recommendations of eccentrically loaded slender concrete-filled tubular columns
نویسندگان
چکیده
منابع مشابه
Ambient and fire behaviour of eccentrically loaded elliptical slender concrete-filled tubular columns
This paper presents the results of an experimental program carried out on slender elliptical hollow section columns filled with concrete. Given the reduced number of experimental results found in the literature on concrete filled tubular columns with elliptical cross-section, the main objective of this paper is to compare the behaviour of such innovative cross-sections under ambient and high te...
متن کاملFire behavior of axially loaded slender high strength concrete - filled tubular columns
This paper describes sixteen fire tests conducted on slender circular hollow section columns filled with normal and high strength concrete, subjected to concentric axial loads. The test parameters were the nominal strength of concrete (30 and 80 MPa), the infilling type (plain concrete, reinforced concrete and steel fiber reinforced concrete) and the axial load level (20% and 40%). The columns ...
متن کاملNumerical Simulation of Ultra- Strength Concrete-filled Steel Columns
Article history: Received: 11. 09. 2013. Received in revised form: 01. 10. 2013. Accepted: 15. 10. 2013. Researches into the constitutive relation of the super high strength and high performance concrete and the stress strain relationship of the ultrastrength concrete-filled steel columns are rare. Therefore, this paper based on continuous mechanics presents the relationship of mathematical des...
متن کاملDetermination of Buckling Loads from Triaxial Load Tests of Slender Concrete-filled Tube Beam-columns
This paper briefly describes efforts at determining buckling loads of slender concrete-filled tube beam-columns. Although utilizing state-of-the-art equipment and controllers, unexpected difficulties were encountered on extracting buckling loads for the specimens due to (a) frictional forces in the actuators, (b) large initial bidirectional imperfections, (c) initial stresses due to constructio...
متن کاملMechanical Behavior of Recycled Aggregate Concrete-Filled Steel Tubular Columns before and after Fire
Recycled aggregate concrete (RAC) is an environmentally friendly building material. This paper investigates the mechanical behavior of recycled aggregate concrete filled steel tube (RACFST) columns exposed to fire. Two groups of 12 columns were designed and tested, under axial compression, before and after fire, to evaluate the degradation of bearing capacity due to fire exposure. Six specimens...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Engineering Structures
سال: 2011
ISSN: 0141-0296
DOI: 10.1016/j.engstruct.2011.01.028