Simple RP-HPLC method for Aceclofenac quantitative analysis in pharmaceutical tablets
نویسندگان
چکیده
منابع مشابه
Simple and Sensitive Method for the Simultaneous Estimation of Drotaverine HCL and Aceclofenac Using RP-HPLC
To develop a simple and sensitive method for the simultaneous estimation of drotaverine HCL (DRH) and aceclofenac (AF) using RP-HPLC. The HPLC separation was achieved on a thermo column (250 mm × 4.6 mm, 5μ) with an isocratic mixture of acetonitrile and 5 mM of ammonium acetate in the ratio of 65:35, pH adjusted to 4.5 at a flow rate of 1.0 ml/min and the detection at 285nm. The method was vali...
متن کاملA Rapid Stability-Indicating RP-HPLC Method for the Determination of Betaxolol Hydrochloride in Pharmaceutical Tablets
A stability-indicating reversed-phase high performance liquid chromatography (RP-HPLC) method was developed for the determination of betaxolol hydrochloride, a drug used in the treatment of hypertension and glaucoma. The desired chromatographic separation was achieved on a Nucleosil C18, 4 μm (150 × 4.6 mm) column, using isocratic elution at a 220 nm detector wavelength. The optimized mobile ph...
متن کاملRapid Rp Hplc Method for Quantitative Determination of Lornoxicam in Tablets
The objective of the study was to develop a simple, rapid, specific and precise reverse phase high performance liquid chromatographic method for the determination of lornoxicam in bulk and pharmaceutical preparations. Chromatographic separation of the drug was performed on a eclipse C18 column (150 mm × 4.6 mm, 5 μm) as stationary phase and mobile phase used is methanol: 0.1% formic acid in wat...
متن کاملMethod Development and Validation of a Stability-Indicating RP-HPLC Method for the Quantitative Analysis of Dronedarone Hydrochloride in Pharmaceutical Tablets
A simple, precise, and accurate HPLC method has been developed and validated for the quantitative analysis of Dronedarone Hydrochloride in tablet form. An isocratic separation was achieved using a Waters Symmetry C8 (100 × 4.6 mm), 5 μm particle size column with a flow rate of 1 ml/min and UV detector at 290 nm. The mobile phase consisted of buffer: methanol (40:60 v/v) (buffer: 50 mM KH2PO4 + ...
متن کاملValidation of UV-Spectrophotometric and RP-HPLC methods for the simultaneous analysis of Paracetamol and Aceclofenac in marketed tablets
The aim of the study was to develop UV-spectrophotometric and RP-HPLC methods for the simultaneous analysis of paracetamol and aceclofenac in marketed tablets. The methods were validated in terms of linearity, accuracy (% Recovery), precision (inter day, intraday and reproducibility) and robustness. Both the methods were linear (R = 0.997-0.999 for UV method and 0.999 for RP-HPLC method) and ac...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Pharmacia
سال: 2020
ISSN: 2603-557X,0428-0296
DOI: 10.3897/pharmacia.67.e57981