Simple Estimation of Bosentan in Tablet Formulation by RP-HPLC

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Simple Estimation of Bosentan in Tablet Formulation by RP-HPLC

A simple, precise, and accurate method is developed and validated for the analysis of Bosentan tablet formulation. The method has shown adequate separation of the ingredients from Tablets. Separation was achieved on a C18 column using a mobile phase consisting of acetonitrile: 10 Mm ammonium acetate (pH 4.5) buffer (70:30, v/v) at a flow rate of 1.0 ml/min and UV detection at 265 nm. This new m...

متن کامل

Estimation of Cefoperazone in marketed formulation by RP-HPLC

A RP-HPLC assay method has been developed and validated for cefoperazone. An isocratic RP-HPLC was developed on a SS Wakosil IIC18 column (250 mm × 4.6 mm i.d., 5 μm) using a mobile phase of phosphate buffer (pH 6.8) and methanol (3:1 v/v) with UV detection at wavelength 254 nm at the flow rate 1 ml/min. The proposed method was validated for sensitivity, selectivity, linearity, accuracy, precis...

متن کامل

A Sensitive RP-HPLC Method for Simultaneous Estimation of Diethylcarbamazine and Levocetirizine in Tablet Formulation

A simple, sensitive and reproducible method was developed and validated for the simultaneous estimation of diethylcarbamazine and levocetirizine in its tablet formulation by reverse phase high performance liquid chromatography using Waters1515 HPLC with UV detector at the λ(max) of 224 nm, using Princeton Sphere-100 C(18) (250×4.6 mm. 5 μ) column. The mobile phase used was 20mM potassium dihydr...

متن کامل

Simultaneous RP-HPLC estimation and validation of ramipril and atorvastatin in bulk and combined tablet formulation

A simple, precise, accurate and reproducible RP-HPLC method was developed and validated for simultaneous estimation of ramipril and atorvastatin in bulk and combined pharmaceutical formulations. Separation of ramipril and atorvastatin was successfully achieved on an Inertsil ODS C18 column (150mm x 4.6mm x 5 μm). The mobile phase consisted of 0.1% ortho phosphoric acid and methanol (60:40, v/v)...

متن کامل

RP-HPLC Method for Simultaneous Estimation of Frusemide and Amiloride Hydrochloride in Tablet Formulation

A new reverse phase high performance liquid chromatography method for the simultaneous estimation of frusemide and amiloride hydrochloride in tablet formulation is developed. The determination was carried out on a HIQ SIL, C18 (250×4.6 mm, 5 µm) column using a mobile phase of 50 mM phosphate buffer solution:acetonitrile (50:50 v/v, pH 3.0). The flow rate was 1.0 ml/min with detection at 283 nm....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: American Journal of Analytical Chemistry

سال: 2012

ISSN: 2156-8251,2156-8278

DOI: 10.4236/ajac.2012.311095