Short-circuit Current Engineering Calculation Method Considering Crowbar Operation Priority Degree of DFIG

نویسندگان

چکیده

Abstract When fault occurs in high wind power proportion grid, the control strategy and external characteristics of plant are affected by voltage drop so traditional short-circuit current engineering calculation is difficult to converge. A method for considering grid node importance evaluation crowbar protection DFIG(double-fed induction generator), proposed. This paper proposes equivalent model DFIG when considers degree indexes, determines weight each index through Delphi method. The operation priority evaluated ensure successful convergence maximum support plants. study case shows that proposed superior

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Behavior of DFIG Wind Turbines with Crowbar Protection under Short Circuit

Doubly Fed Induction Generators DFIG are nowadays widely used in variable speed wind power plants. The dynamic interaction between variable speed DFIG wind turbines and the power system which is subjected to disturbances, such as short circuit faults, is an important issue. The ability of the wind power plant to stay connected to the grid during disturbances is important to avoid a cascading ef...

متن کامل

Short Circuit Calculation Methods

All electrical systems are susceptible to short circuits and the abnormal current levels they create. These currents can produce considerable thermal and mechanical stresses in electrical distribution equipment. Therefore, it's important to protect personnel and equipment by calculating short-circuit currents during system upgrade and design. Because these calculations are life-safety related, ...

متن کامل

Vectorized Calculation of Short Circuit Currents Considering Distributed Generation - An Open Source Implementation of IEC 60909

An important task in grid planning is to ensure that faults in the grid are detected and cut off without damage in any grid element. Calculating short circuit currents is therefore a vital grid analysis functionality for grid planning applications. The standard IEC 60909 provides guidelines for short circuit calculations and is routinely applied in grid planning applications. This paper present...

متن کامل

crystalline silicon solar cell engineering to improve fill factor, open circuit voltage, short circuit current and overall cell efficiency

design and optimization of a single crystalline silicon (c-si) solar cell is performed to achieve the maximum light conversion efficiency. various parameters such as doping concentration and thicknesses, and geometrical dimension of surface pyramids are studied. the inverted surface pyramid is used to increase the efficiency of the solar cell, and engineered oxide layer is used as the passivati...

متن کامل

Fault Behavior of Wind Turbines

Synchronous generators have always been the dominant generation type in the grid. This fact affected both planning and operation of power systems. With the fast increase of wind power share in the grid in the last decade, the situation is changing. In some countries wind power represents already a consistent amount of the total generation. Wind turbines can be classified as non-synchronous gene...