Shear Strengthening of T Cross Section Reinforced Concrete Beams by Near-Surface Mounted Technique
نویسندگان
چکیده
منابع مشابه
Shear strengthening of reinforced concrete beams with CFRP
The current paper reviews existing design guidelines for strengthening beams in shear with carbon fibre reinforced polymer (CFRP) sheets and proposes a modification to Concrete Society Technical Report TR55. It goes on to present the results of an experimental programme which evaluated the contribution of CFRP sheets towards the shear strength of continuous reinforced concrete (RC) beams. A tot...
متن کاملShear Area of Reinforced Concrete Circular Cross-section Members
The shear strength of reinforced concrete members without shear reinforcement is related to the shear stress carried by the concrete effective shear area. For rectangular sections the effective shear area represents the area corresponding to the effective depth. However, for circular sections this area is not as readily defined. Different empirical proposals have been suggested recently but no ...
متن کاملShear strength model of reinforced concrete circular cross-section members
A shear capacity model of reinforced concrete members with circular cross section transversely reinforced with circular hoops has been developed. The proposed model is based on the truss analogy by adding a concrete contribution term to the capacity of the shear reinforcement. An additional deviatoric shear resisting th c curv pres nism ste ved und ctor mechanism of hoops present solely in memb...
متن کاملStrengthening of Shear Deficient Reinforced Concrete Beams Retrofitted with Cement-based Composites
The restoration of strength and stiffness of damaged reinforced concrete beams with deficient reinforcements, through retrofitting, was experimentally and numerically studied. Retrofitting is carried out by wrapping glass fiber strips using cement-based composite binders. Six beams of size 1500mm (length) x100mm (width) x 150mm (depth) have been tested in four-point bending. Three beams are use...
متن کاملStrengthening reinforced concrete T connections by steel straps
The aim of this paper is to present results of testing a full scale reinforced concrete T connection by static loading. The connection is a T connection representing a beam-column connection. The beam and column had a square cross section with a 300 mm dimension. The height of the column was 2.9 m and the clear beam length was 1.4 m. The connection was initially tested to failure. Galvanised st...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Composites for Construction
سال: 2008
ISSN: 1090-0268,1943-5614