Sensitivity Analysis of a Magnetic Circuit for Non-Destructive Testing by the Magnetic Flux Leakage Technique
نویسندگان
چکیده
منابع مشابه
Detection of Mechanical Damage Using the Magnetic Flux Leakage Technique
Since magnetism is strongly stress dependent, Magnetic Flux Leakage (MFL) inspection tools have the potential to locate and characterize mechanical damage in pipelines. However, MFL application to mechanical damage detection faces hurdles which make signal interpretation problematic: 1) the MFL signal is a superposition of geometrical and stress effects, 2) the stress distribution around a mech...
متن کاملMagnetic Flux Leakage and Acoustic Emission Testing Technique for Atmospheric Storage tanks
In china, atmospheric storage tanks are not included in the management of special equipment, and therefore they are not required to be inspected compulsorily. There is larger difference between China and developed countries on atmospheric storage tank inspection technique than the other techniques on the inspection of pressure vessels. It is widely believed that the strength worsening and perfo...
متن کاملAnalysis of a non-destructive evaluation technique for defect characterization in magnetic materials using local magnetic measurements
In this paper we study a method for non-destructive testing of laminated strips of a non-linear magnetic material. Based on local measurements of the magnetic induction at the surface, we are able to reconstruct the proper position of defects inside the material, by solving an inverse problem. This inverse problem is solved by minimizing a suitable cost function using a gradient based optimizat...
متن کاملGiant Magneto-Resistive (GMR) Sensors for Non-Destructive Detection of Magnetic Flux Leakage from Sub-Surface Defects in Steel
There is an increasing demand for using high sensitive sensors which can detect very low levels of magnetic flux leakage from hidden defects or far-side wall loss due to pitting or local corrosion in ferromagnetic steels. This paper discusses the use of highly sensitive tiny GMR sensors for detection of sub-surface defects in carbon steel plates. Notches located at different depths below surfac...
متن کاملA Lift-Off-Tolerant Magnetic Flux Leakage Testing Method for Drill Pipes at Wellhead
To meet the great needs for MFL (magnetic flux leakage) inspection of drill pipes at wellheads, a lift-off-tolerant MFL testing method is proposed and investigated in this paper. Firstly, a Helmholtz coil magnetization method and the whole MFL testing scheme are proposed. Then, based on the magnetic field focusing effect of ferrite cores, a lift-off-tolerant MFL sensor is developed and tested. ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Prospectiva
سال: 2016
ISSN: 2216-1368,1692-8261
DOI: 10.15665/rp.v14i2.678