AIM To compare using scanning electron microscopy (SEM) root canal walls following instrumentation in vitro with two different rotary NiTi instruments. The hypothesis was that no difference should be observable between the experimental groups in terms of debris on canal walls and surface morphology. METHODOLOGY Twenty-four single-rooted human teeth were selected. Two types of NiTi instruments...
متن کاملComparison of Two Canal Preparation Techniques Using Mtwo Rotary Instruments
INTRODUCTION Root canal preparation is an important process in endodontic therapy. Nickel-titanium (NiTi) rotary file system can be used in single length technique (simultaneous technique) without early coronal enlargement, as well as in crown-down method. The purpose of this in vitro study was to compare single length with crown-down methods' shaping ability using Mtwo NiTi files. MATERIALS ...
متن کاملCanal Centring Ability of ProTaper and Mtwo Rotary Systems in Curved Canals
The purpose of this investigation was to compare centring ratio of ProTaper and Mtwo rotary systems. 60 mandibular molar teeth which had 25, 30 and 35 degree curvature in mesio-buccal root canal were used. Group 1 had 25°, Group 2 had 30°, and Group 3 had 35° curvatures. The roots were sectioned horizontally at 2 mm away from the apex. The apical region was then observed under a stereo-microsco...
متن کاملComparison of air-driven vs electric torque control motors on canal centering ability by ProTaper NiTi rotary instruments.
AIM Cleaning and shaping is one of the most important phases in root canal therapy. Various rotary NiTi systems minimize accidents and facilitate the shaping process. Todays NiTi files are used with air-driven and electric handpieces. This study compared the canal centering after instrumentation using the ProTaper system using Endo IT, electric torque-control motor, and NSK air-driven handpiece...
متن کاملCyclic Fatigue Resistance and Fractographic Analysis of Race and Protaper Rotary NiTi Instruments
INTRODUCTION This study investigated the fatigue and fracture modes of RaCe and ProTaper rotary instruments. MATERIALS AND METHODS Fatigue resistance was evaluated by rotating the files 30° or 60° and with 2 or 5mm radius of curvature. RaCe taper 06 size 25 and ProTaper F1 files (n=40) were used. The number of rotations to failure was analyzed by two-way ANOVA and independent sample t-test. F...