منابع مشابه
Resistance of endotracheal tubes measured after extubation in ICU patients
Methods The study was performed over patients intubated for at least 1 day in our ICU. Once the patient was extubated, tube was immediately stored in a plastic bag at room temperature and kept in a safe place until bench assessment. This was performed maximal 24 hours after extubation as follows. The endotracheal tube was attached to a filter (Hygrobac) and both were set to ASL 5000 active serv...
متن کاملMechanical ventilation in obese ICU patients: from intubation to extubation
This article is one of ten reviews selected from the Annual Update in Intensive Care and Emergency Medicine 2017. Other selected articles can be found online at http://ccforum.com/series/annualupdate2017 . Further information about the Annual Update in Intensive Care and Emergency Medicine is available from http://www.springer.com/series/8901 .
متن کاملICU CORNER: Mechanical ventilation: Weaning and extubation
GENERAL INFORMATION ICU CORNER is a section of OPUS 12 Scientist dedicated to brief topic reviews geared toward preparation for the various Critical Care Board Examinations. Each quarterly edition of OPUS 12 Scientist will contain one or two condensed overviews, accompanied by a list of selected references. Contributions via regular article submission process are welcome, subject to Editorial B...
متن کاملExtubation failure in a large pediatric ICU population.
OBJECTIVE To review a large population of children receiving mechanical ventilation to establish a baseline rate of extubation success and failure and to identify those characteristics that place a patient at greater risk of failing planned extubation. DESIGN Retrospective chart review. SETTING University-affiliated children's hospital with a 20-bed pediatric ICU. PATIENTS All 632 patient...
متن کاملBench study of automated tube compensation versus pressure support after extubation in icu patients
Methods Once removed the endotracheal tube from patients, who were extubated in our ICU after successful weaning trial, was connected to a filter (Hygrobac), and both were attached to ASL 5000 active servo lung (IngMar medical). The lung model was set with a compliance of 50 ml/ cmH2O and resistance of 10 cm H2O/L/s. The inspiratory effort included sinusoidal half-wave shape, muscular pressure ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: The Southwest Respiratory and Critical Care Chronicles
سال: 2014
ISSN: 2325-9205
DOI: 10.12746/swrccc.v2i8.169