Scleral Buckle Extrusion Associated with Phthisis
نویسندگان
چکیده
منابع مشابه
Scleral Buckle Extrusion Associated with Phthisis
Exposure of implanted episcleral element is a rare complication of buckling procedures. We describe a 40-year-old man who presented to our clinic complaining of foreign body sensation and irritation in his left eye which lasted several months. The patient history was positive for bilateral rhegmatogenous retinal detachment which was treated with sclera buckling. Upon presentation the left eye d...
متن کاملBaerveldt drainage implants in eyes with a preexisting scleral buckle.
OBJECTIVE To describe the surgical insertion of a Baerveldt drainage implant and postoperative visual acuity and intraocular pressure (IOP) outcomes in patients with a preexisting scleral buckle. METHODS Medical records of all patients with a preexisting scleral buckle who underwent insertion of a Baerveldt drainage implant at Bascom Palmer Eye Institute, Miami, Fla, from January 1, 1994, thr...
متن کاملA rare case of scleral buckle infection with Curvularia species
BACKGROUND Scleral buckling is an established modality of treating retinal detachment. Being an external implant the buckle may be prone to infections. We report such a case with a delayed presentation and a rare etiology. CASE PRESENTATION A 45 year old male presented with redness, foreign body sensation and discharge for one month in his right eye. The patient had undergone a retinal detach...
متن کاملSecondary Glaucoma Associated with Encircling Scleral Buckle Migration into the Cornea
Transmuscular migration of the encircling band through rectus muscles and straddling of the cornea has only been reported in a few cases previously in the literature. This rare condition has never been associated with glaucoma. In this report, we aimed to describe a unique case with transmuscular migration of encircling buckle as a probable cause of glaucoma. A 17-year-old female presented with...
متن کاملIs it time to call time on the scleral buckle?
O vernight, an extensive pool of subretinal fluid (SRF) disappears following the judicious application of a small plomb over a peripheral U-tear, and one can only marvel at the underlying mechanisms at play. The scleral indentation has somehow overcome the dynamic tractional forces operating in the region of the break, allowing it to close; and the ‘‘pigment epithelial pump’’ has obligingly dri...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Case Reports in Ophthalmological Medicine
سال: 2011
ISSN: 2090-6722,2090-6730
DOI: 10.1155/2011/942946