Scintrex CG5 used for superconducting gravimeter calibration

نویسندگان

چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Superconducting gravimeter calibration by co-located gravity observations – results from GWR C025

After a 12 years’ observation in Vienna (VI), the superconducting gravimeter GWR C025 has been transferred in autumn 2007 to the new Conrad observatory (CO) 60 km SW of Vienna. It is one of few instruments which were operated at different stations. This aspect motivated a re-analysis of all calibration experiments performed so far in VI and CO, focused on the direct impact of drift effects and ...

متن کامل

The Superconducting Gravimeter as a Field Instrument Applied to Hydrology

We describe development of a transportable version of the Superconducting Gravimeter (SG) and its test in a field experiment to monitor storage in a karst (limestone) aquifer in central Texas. The SG is contained within two aluminum enclosures, one holding the SG in its 35 liter helium dewar, plus electronics; and the second for refrigerator and power supply. In the field test, the SG was suppo...

متن کامل

Studies of Earth Dynamics with the Superconducting Gravimeter

I present investigations of Earth dynamics with the superconducting gravimeter GWR T020 at Metsähovi from 1994 to 2005. As a necessary background, the history and key technical details of the installation are given. Then a new data acquisition system (DAS) developed by the author is described. It has proved reliable and accurate. A pre-requisite for the study of weak phenomena is the removal of...

متن کامل

Field test of the superconducting gravimeter as a hydrologic sensor.

We report on a field test of a transportable version of a superconducting gravimeter (SG) intended for groundwater storage monitoring. The test was conducted over a 6-month period at a site adjacent to a well in the recharge zone of the karstic Edwards Aquifer, a major groundwater resource in central Texas. The purpose of the study was to assess requirements for unattended operation of the SG i...

متن کامل

Analysis and calibration techniques for superconducting resonators.

A method is proposed and experimentally explored for in-situ calibration of complex transmission data for superconducting microwave resonators. This cryogenic calibration method accounts for the instrumental transmission response between the vector network analyzer reference plane and the device calibration plane. Once calibrated, the observed resonator response is analyzed in detail by two app...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Geodesy and Geodynamics

سال: 2018

ISSN: 1674-9847

DOI: 10.1016/j.geog.2017.02.009