Salvage of Suboptimal Enhancement of Pulmonary Artery in Pulmonary CT Angiography Studies: Rapid kVp Switch Dual Energy CT Experience
نویسندگان
چکیده
منابع مشابه
Overuse and underuse of pulmonary CT angiography in patients with suspected pulmonary embolism
Background: The aim of the present study was to evaluate the utilization and diagnostic yields of CT pulmonary angiography (CTPA) using the Revised Geneva score and Wells’ criteria, in patients with suspected pulmonary embolism (PE). Methods: One hundred and twelve adult patients underwent CTPA for suspected PE were participated in this study. The outcome was positive or neg...
متن کاملDual-energy CT pulmonary angiography of pulmonary embolism: comparison of image quality and clot visualisation at 80 kvp, 140 kvp and weighted average images
متن کامل
Evaluation of CT angiography findings in the patients with clinical diagnosis of pulmonary thromboembolism
Background and Aim: Pulmonary thromboembolism is an important clinical problem in the patients after major surgeries and is often difficult to diagnose because of nonspecific clinical symptoms. Diagnosis of pulmonary embolism is based on medical imaging methods. The aim of this study was to evaluate the results of CT pulmonary angiographies of the patients with primary clinical diagnosis of pul...
متن کاملDual energy CT pulmonary angiography: findings in a patient with chronic thromboembolic pulmonary hypertension.
A 55-year-old woman became increasingly breathless over a 9month period. Systolic pulmonary artery pressure was estimated at 50 mm Hg by echocardiography. CT pulmonary angiography was performed using a dual energy technique whereby datasets are simultaneously acquired at 80 kV and 140 kV. Differential absorption of these energy spectra by iodine molecules in intravenous contrast medium is explo...
متن کاملEvaluation of the confounding factors disturbing the quality of CT images of pulmonary angiography
Background: Since pulmonary angiography is the only non-invasive method for diagnosing pulmonary embolism, the use of radiation reduction methods without affecting the quality of images seems necessary. One of the simplest reasons for unnecessarily increasing of patient exposure is repetitive imaging due to poor image quality. Therefore, it is necessary to identify and ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Iranian Journal of Radiology
سال: 2020
ISSN: 1735-1065,2008-2711
DOI: 10.5812/iranjradiol.97230