Stress Degradation Studies And Validation Method For Quantification Of Aprepitent In Formulations By Using RP-HPLC

A Stability indicating reverse phase high performance liquid chromatography method has been developed for the estimation of Aprepitant in tablet dosage form. A Thermosil symmetry C18 column having dimensions of 150×4.6mm and 5μm particle size, with mobile phase containing a mixture of water and Acetonitrile in the ratio of 30:70 v/v was used. The flow rate was 1ml/min and the column effluents w...

متن کامل

Method development and validation of chlordiazepoxide and amitryptyline hydrochloride in pharmaceutical formulations by RP-HPLC

A simple, precise and rapid, reversed phase-high performance liquid chromatography (RP-HPLC) method is developed for simultaneous determination of chlordiazepoxide and amitriptyline hydrochloride in tablet dosage forms. The HPLC conditions used are methanol: acetonitrile (75:25 v/v) mobile phase, Zodiac C18 column (250mm x 4.6mm x 5μm), pump pressure (9.5 MPa) and detection wavelength (221 nm)....

متن کامل

Development and Validation of Rp-hplc Method for Estimation of Milnacipran Hcl in Pharmaceutical Formulations

A new simple isocratic RP-HPLC method was developed for the determination of milnacipran in bulk drug and in its capsules formulations. The mobile phase selected was methanol: acetonitrile:0.1% O-phosphoric acid in the ratio of 55:35:10%(v/v) and Zodiac C18 column with dimensions (250X4.6mm, 5μ)was used as stationary phase column temperature is ambient throughout the method. The flow rate and w...

متن کامل

Development and validation of RP-HPLC method for estimation of Cefotaxime sodium in marketed formulations.

A RP-HPLC assay method has been developed and validated for cefotaxime. An isocratic RP-HPLC was developed on a SS Wakosil II- C8 column (250 mm ˜4.6 mm i.d., 5 μm) utilizing a mobile phase of ammonium acetate buffer (pH 6.8) and acetonitrile (85:15 v/v) with UV detection at wavelength 252 nm at the flow rate 0 .8 ml/min. The proposed method was validated for sensitivity, selectivity, linearity...

متن کامل

Development and validation of RP HPLC method to determine nandrolone phenylpropionate in different pharmaceutical formulations.

This study describes development and subsequent validation of a reversed phase high performance liquid chromatographic (RP-HPLC) method for the estimation of nandrolone phenylpropionate, an anabolic steroid, in bulk drug, in conventional parenteral dosage formulation and in prepared nanoparticle dosage form. The chromatographic system consisted of a Luna Phenomenex, CN (250 mm x 4.6 mm, 5 micro...