RETRACTED ARTICLE: Identification of plastic hinge length for pre-tensioning confined HSC columns
نویسندگان
چکیده
منابع مشابه
Compressive Strength of Confined Concrete in CCFST Columns
This paper presents a new model for predicting the compressive strength of steel-confined concrete on circular concrete filled steel tube (CCFST) stub columns under axial loading condition based on Artificial Neural Networks (ANNs) by using a large wide of experimental investigations. The input parameters were selected based on past studies such as outer diameter of column, compressive strength...
متن کاملAnalysis of Rotational Column with Plastic Hinge
Michael Long, Rice University; Corey Bergad, Bates College; EERC Name: MCEER Host Institution: SUNY at Buffalo Faculty Advisor: Dr. Andrei Reinhorn ________________________________________________________________________ Abstract: A plastic hinge is a type of energy dampening device allowing plastic rotation of an otherwise rigid column connection. This device is composed of a weakened portion ...
متن کاملBehavior of Confined Columns under Different Techniques
Since columns are the most important elements of the structures, failure of one column in a critical location can cause a progressive collapse. In this respect, the repair and strengthening of columns is a very important subject to reduce the building failure and to keep the columns capacity. Twenty columns with different parameters is tested and analysis. Eleven typical confined reinforced con...
متن کاملCompressive Strength Prediction by ANN Formulation Approach for FRP Confined Rectangular Concrete Columns
Enhancement of strength and ductility is the main reason for the extensive use of FRP (fiber reinforced polymer) jackets to provide external confinement to reinforced concrete columns especially in seismic areas. Therefore, numerous researches have been carried out in order to provide a better description of the behavior of FRP confined concrete for practical design purposes. This study present...
متن کاملPlastic Hinge Integration Methods for Force-Based Beam–Column Elements
A new plastic hinge integration method overcomes the problems with nonobjective response caused by strain-softening behavior in force-based beam–column finite elements. The integration method uses the common concept of a plastic hinge length in a numerically consistent manner. The method, derived from the Gauss–Radau quadrature rule, integrates deformations over specified plastic hinge lengths ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: KSCE Journal of Civil Engineering
سال: 2016
ISSN: 1226-7988,1976-3808
DOI: 10.1007/s12205-016-1128-7