Restrike characteristics of vacuum circuit breaker in its opening process under DC voltage

نویسندگان

چکیده

The restrike of vacuum circuit breaker during the breaking process causes overvoltage and intensifies insulation deterioration high-voltage equipment. To solve this problem, aging test method characteristics are researched. A withstand voltage platform 40.5-kV was established to obtain effects contact spacing loop inrush currents on number restrike, wavefront steepness breakdown voltage, duration. decreased duration repeated-breakdown arc increased with breaker. As current system increased, breaker, increased. amplitude closing results provide a theoretical basis data support for preventive optimization test.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

3D MHD modelling of low current – high voltage DC plasma torch under restrike mode

We present in this paper a MHD modelling of the gliding arc behaviour of a DC plasma torch operating with air under low current and high voltage conditions. The low current leads to instabilities and difficulties to simulate the process because the magnetic field is not sufficient to constrict the arc. The model is 3D, time-dependent and the MHD equations are solved in using CFD software Code_S...

متن کامل

SF6 High Voltage Circuit Breaker Contact Systems Under Lightning Impulse and Very Fast Transient Voltage Stress

In the past few years gas insulated high voltage circuit breakers have improved considerably, in particular with respect to required drive energy for operation, compactness and reliability. A further reduction in size implies increasing operational field stress inside the breaker and, thus, a reduction in built-in safety margins. If the design comes closer to its physical limits, in particular ...

متن کامل

Assessing of Circuit Breaker Restrike Risks Using Computer Simulation and Wavelet Analysis

A breaker restrike is an abnormal arcing phenomenon, leading to a possible breaker failure. Eventually, this failure leads to interruption of the transmission and distribution of the electricity supply system until the breaker is replaced. Before 2008, there was little evidence in the literature of monitoring techniques based on restrike measurement and interpretation produced during switching ...

متن کامل

Current-Voltage Characteristics of DC Discharge in Micro Gas Jet Injected into Vacuum Environment

A current-voltage characteristic of direct current (DC) gas discharge operated in a micro gas jet injected into a secondary electron microscope (SEM) chamber is presented. Ar gas was injected through a 30 μm orifice gas nozzle (OGN) and was evacuated by an additional pump to keep the high vacuum environment. Gas discharges were ignited between the OGN as anode and a counter electrode of Si wafe...

متن کامل

Voltage Equalization of DC Link capacitors in a CHB-Based PET under the Unbalance Voltage Conditions

The unbalance currents injection by power electronic transformers in order to improve the unbalance voltage conditions of the network causes an imbalanced voltage in the DC link capacitors and creates an active powers inequality in the different phases. In this paper, the proposed control structure independently controls the active power of each phase by modifying the power angle between the vo...