Respiratory motion estimation of the liver with abdominal motion as a surrogate
نویسندگان
چکیده
منابع مشابه
The influence of respiratory motion on dose distribution of 3D-CRT and IMRT- A simulation study
Background: 3DCRT (three-dimensional conformal radiotherapy) and IMRT (intensity-modulated radiotherapy) has provided us with tools to delineate the radiation dose distribution of tumor targets. However, the precision of radiation can be compromised by respiratory motion, which usually limits the geometric and dosimetric accuracy of radiotherapy. The purpose of this study is to evaluate the imp...
متن کاملMethods for abdominal respiratory motion tracking
Non-invasive surface registration methods have been developed to register and track breathing motions in a patient's abdomen and thorax. We evaluated several different registration methods, including marker tracking using a stereo camera, chessboard image projection, and abdominal point clouds. Our point cloud approach was based on a time-of-flight (ToF) sensor that tracked the abdominal surfac...
متن کاملHaptic Simulation of the Liver with Respiratory Motion
During a standard procedure of liver biopsy, the motion due to respiration may be difficult to handle. The patient is often requested to hold his breath or to breathe shallowly. Ideally, this physiological behaviour should be taken into account in a virtual reality biopsy simulator. This paper presents a framework that accurately simulates respiratory motion, allowing for the fine tuning of rel...
متن کاملAutoadaptive motion modelling for MR-based respiratory motion estimation
Respiratory motion poses significant challenges in image-guided interventions. In emerging treatments such as MR-guided HIFU or MR-guided radiotherapy, it may cause significant misalignments between interventional road maps obtained pre-procedure and the anatomy during the treatment, and may affect intra-procedural imaging such as MR-thermometry. Patient specific respiratory motion models provi...
متن کاملMotion Estimation Model for Cardiac and Respiratory Motion Compensation
Catheter ablation is widely accepted as the best remaining option for the treatment of atrial fibrillation if drug therapy fails. Ablation procedures can be guided by 3-D overlay images projected onto live fluoroscopic X-ray images. These overlay images are generated from either MR, CT or C-Arm CT volumes. As the alignment of the overlay is often compromised by cardiac and respiratory motion, m...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: The International Journal of Medical Robotics and Computer Assisted Surgery
سال: 2018
ISSN: 1478-5951
DOI: 10.1002/rcs.1940