Respiratory Motion Detection and Correction in ECG-Gated SPECT: a New Approach
نویسندگان
چکیده
منابع مشابه
Respiratory Motion Detection and Correction in ECG-Gated SPECT: a New Approach
OBJECTIVE Gated myocardial perfusion single-photon emission computed tomography (GSPECT) has been established as an accurate and reproducible diagnostic and prognostic technique for the assessment of myocardial perfusion and function. Respiratory motion is among the major factors that may affect the quality of myocardial perfusion imaging (MPI) and consequently the accuracy of the examination. ...
متن کاملA New Approach for Motion Correction in SPECT Imaging
Due to the long imaging times in SPECT, patient motion is inevitable and constitutes a serious problem for any reconstruction algorithm. The measured inconsistent projection data lead to reconstruction artifacts which can significantly affect the diagnostic accuracy of SPECT if not corrected. Among the most promising attempts for addressing this cause of artifacts is the so-called data-driven m...
متن کاملMotion Correction on Dual ECG and Respiratory Gated 3D Cardiac PET/CT Data
Gating The PET was divided into six respiratory and six cardiac phases. The respiratory signal was acquired by tracking the position of a white spot on a black disc placed on the abdomen of the patient with a video camera. A LED diode was used for synchronizing the respiratory signal with the listmode PET data. The ECG signal was acquired using the ECG port of the scanner. The PET data was then...
متن کاملA new approach to scatter correction in SPECT images based on Klein_Nishina equation
Introduction: Scattered photon is one of the main defects that degrade the quality and quantitative accuracy of nuclear medicine images. Accurate estimation of scatter in projection data of SPECT is computationally extremely demanding for activity distribution in uniform and non-uniform dense media. Methods: The objective of this paper is to develop and validate a scatter correction technique ...
متن کاملRespiratory motion correction in prostate cancer positron emission tomography: A study on patients and phantom simulation
Introduction: To investigate the effects of breathing cycle and tree diaphragm motions on prostate cancer tumors standard uptake value (SUV) during positron emission tomography (PET) and to correct it. Materials and methods: Respiratory motion traces were simulated on the common patient breathing cycle and tree diaphragm motio...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Korean Journal of Radiology
سال: 2008
ISSN: 1229-6929
DOI: 10.3348/kjr.2008.9.6.490