Replacement ion chromatography with potentiometric detection using a potassium-selective membrane electrode
نویسندگان
چکیده
منابع مشابه
Potentiometric Determination of Dopamine Using a Solid-Contact Polymer Membrane Ion-Selective Electrode
Potentiometric Determination of Dopamine Using a Solid-Contact Polymer Membrane Ion-Selective Electrode Tanji Yin1 2 3 ∗ and Wei Qin1 1Key Laboratory of Coastal Zone Environmental Processes, Yantai Institute of Coastal Zone Research YIC , Chinese Academy of Sciences CAS ; Shandong Provincial Key Laboratory of Coastal Zone Environmental Processes, YICCAS, Yantai, Shandong 264003, P. R. China 2So...
متن کاملKinetic potentiometric determination of creatinine in serum with a picrate ion-selective membrane electrode.
We describe a new kinetic method for potentiometric determination of creatinine in serum, based on the creatinine--picrate reaction in alkaline medium (Jaffé reaction). The reaction is monitored with a picrate-selective electrode, and the increase in electrode potential during 270 s is measured and related directly to the creatinine concentration. Small cation-exchange columns are used to separ...
متن کاملSelective Membrane Electrode for Bromide Ion Based on Aza Pyrilium Ion Derivative as a new Ionophore.
A highly selective electrode for Bromide ion based on aza pyrilium derivative as an excellentionophore is described.The sensor exhibits a good linear response with a slope of ( 60±1 ) mV per decadeover the concentration range of ( 1×10-3 – 9×10-6 M ) , and a detection limit of ( 3×10-6 M ) of Bromideions .The electrode response is independent of pH in the range of(4.0 –9.5).Selectivity coeffici...
متن کاملDetermination of potassium ion concentration in serum using a highly selective liquid-membrane electrode.
The potassium-selective glass membranes like KAS,,_, and NAS,,_, are approx. IO times more sensitive to K+ than to Na +lp3. Since the concentration ratio of Na+/K+ in blood serum is around 35-40 and since there is at best a K+ over Naf selectivity in glass electrodes of IO, a separate measurement of the Na+ concentration is needed to correct the reading of the K+ sensor 4. Because of the depend...
متن کاملRational design of potentiometric trace level ion sensors. A Ag+-selective electrode with a 100 ppt detection limit.
Submicromolar to picomolar lower detection limits have recently been obtained with various polymer membrane ion-selective electrodes by minimizing biases due to ion fluxes through the membrane. For the best performance, the compositions of the membrane and inner solution should be optimized for each application. Given the number of parameters to be adjusted, it has been difficult to find the be...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Analytica Chimica Acta
سال: 1989
ISSN: 0003-2670
DOI: 10.1016/s0003-2670(00)81883-8