RELATIONSHIP BETWEEN TIDAL VOLUME AND DEADSPACE DURING HIGH FREQUENCY VENTILATION

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Small tidal volume ventilation using a zero deadspace tracheal tube.

The zero deadspace tracheal tube (ZEDS-TT) is a double-lumen endobronchial tube with a truncated bronchial limb. Functionally it is unrelated to the familiar endobronchial tube used in lung isolation surgery. It is placed in the same position as a regular tracheal tube and, by means of special connectors, one limb is used for inspiration and the other for expiration, thereby greatly reducing an...

متن کامل

High-frequency percussive ventilation: pneumotachograph validation and tidal volume analysis.

INTRODUCTION High-frequency percussive ventilation (HFPV) is an increasingly used mode of mechanical ventilation, for which there is no proven real-time means of measuring delivered tidal volume (V(T)). OBJECTIVE To validate a pneumotachograph for HFPV and then exploit flow-sensor data to describe the behavior of both low-frequency and high-frequency breaths. METHODS Sensor performance was ...

متن کامل

Estimating lung volume during high frequency ventilation

The primary goals of lung ventilation are to bring oxygen into the alveoli from where it can enter the blood, and to eliminate carbon dioxide dissolved in the blood. Since CO2 is much more soluble in blood than oxygen, O2 transport is diffusion-limited and a large alveolar surface area is the primary factor controlling its delivery. CO2 transport is flow-limited, so that efficient gas transport...

متن کامل

High-frequency percussive ventilation and low tidal volume ventilation in burns: a randomized controlled trial.

OBJECTIVES In select burn intensive care units, high-frequency percussive ventilation is preferentially used to provide mechanical ventilation in support of patients with acute lung injury, acute respiratory distress syndrome, and inhalation injury. However, we found an absence of prospective studies comparing high-frequency percussive ventilation with contemporary low-tidal volume ventilation ...

متن کامل

Carbon dioxide clearance and deadspace during high frequency jet ventilation. Investigations in the dog.

The effects of frequency, tidal volume and added deadspace on carbon dioxide clearance were measured during high frequency jet ventilation at 1, 3 and 5 Hz in dogs. With a short, small volume deadspace, carbon dioxide clearance increased with minute volume at each frequency, but for a given minute volume the clearance decreased with increase in frequency. At 5 Hz, carbon dioxide clearance was l...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: British Journal of Anaesthesia

سال: 1986

ISSN: 0007-0912

DOI: 10.1093/bja/58.1.11