Reinforced flexural elements for temp-stress program
نویسندگان
چکیده
منابع مشابه
Flexural modulus, flexural strength, and stiffness of fiber-reinforced posts.
BACKGROUND The radiopacity degree of posts is not enough for adequate visualization during radiographic analyses. Glass fiber post with stainless steel reinforcement has been fabricated in an attempt to overcome this limitation. AIM This study was designed to determine the influence of this metal reinforcement on the post mechanical properties. MATERIALS AND METHODS This study evaluated fle...
متن کاملFlexural Behavior of Reinforced HPFRCC Beams
High Performance Fiber Reinforced Cementitious Composite (HPFRCC) materials exhibit strain hardening behavior with multiple cracking under tensile loading. In this paper, experimental and parametric studies are performed to assess the influence of using HPFRCC material instead of normal concrete in reinforced concrete beams. After calibrating the experimental results, the analytical results inc...
متن کاملProbabilistic Flexural Fatigue in Plain and Fiber-Reinforced Concrete
The objective of this work is two-fold. First, we attempt to fit the experimental data on the flexural fatigue of plain and fiber-reinforced concrete with a probabilistic model (Saucedo, Yu, Medeiros, Zhang and Ruiz, Int. J. Fatigue, 2013, 48, 308-318). This model was validated for compressive fatigue at various loading frequencies, but not for flexural fatigue. Since the model is probabilistic...
متن کاملExperimental Investigations on The Flexural Strength of PET Reinforced Concrete
Due to the rapid industrialization taking place globally, the problems generated are acute shortage of construction material and increasing in productivity of wastes. The production and consumption of plastic and the rate at which solid plastic waste (SPW) are created have increased considerably. Plastics constitute 12.3% of total waste produced most of which is from discarded water bottles. Th...
متن کاملFlexural Cracks in Fiber-Reinforced Concrete Beams with Fiber-Reinforced Polymer Reinforcing Bars
Fiber-reinforced polymer (FRP) reinforcing bars have aTtracted considerable 0llellli0l1 for applications where corrosion of steel reinforcement is problemaric. Due 10 rhe generally low elastic modulus and poor bond clwracreristics of FRP as coil/pared 10 steel reinforcing bars, the use of FRP results in IGI:i?er crack widlhs under senJice loads. Fiber-reinforced concrete (FRe) is proposed for u...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Nuclear Engineering and Design
سال: 1988
ISSN: 0029-5493
DOI: 10.1016/0029-5493(88)90271-3