Reduction behavior of insecticide azoxystrobin and its voltammetric determination using silver solid amalgam electrode
نویسندگان
چکیده
منابع مشابه
Voltammetric determination of dinitronaphthalenes using a silver solid amalgam paste electrode.
The electrochemical behavior and application of a new sensor, a silver solid amalgam paste electrode (AgSA-PE), based on the mixture of a fine silver solid amalgam powder (60:40 (w(Hg)/w(Ag))) and a suitable organic pasting liquid (Paraffin oil) in a ratio of 20:1 (w/w), was investigated in an aqueous-methanolic media (1:1). This alternative working electrode provides simple preparation and han...
متن کاملVoltammetric determination of Nordiazepam at meniscus modified silver solid amalgam electrode
New electrochemical method for determination of Nordiazepam (NDZ) at meniscus modified silver solid amalgam electrode (m-AgSAE) was developed utilizing differential pulse voltammetry (DPV). The pH effect on the current response of NDZ was studied in the mixture of Britton-Robinson buffer (BR) and methanol (9:1) with optimum pH value of 10. The calibration dependences were examined under the opt...
متن کاملVoltammetric Determination of Acibenzolar-S-Methyl Using a Renewable Silver Amalgam Film Electrode
Acibenzolar-S-methyl (ASM) is a novel fungicide applied for crop protection. A renewable silver amalgam film electrode was used for the determination of ASM in pH 3.4 Britton Robinson buffer using square wave adsorptive stripping voltammetry (SWAdSV). The parameters of the method were optimized. The electroanalytical procedure made possible to determine ASM in the concentration range of 5 10 –3...
متن کاملVoltammetric determination of folic Acid using liquid mercury free silver amalgam electrode.
The electrochemical behavior of folic acid (FA) on a polished silver solid amalgam electrode (p-AgSAE), as a liquid mercury free electrode, has been studied in this paper. Differential pulse voltammetry (DPV) was found as a suitable method for voltammetric determination of folic acid. A limit of detection as 5.88 × 10-10 M (after 60 s of accumulation) was calculated for FA determination in an a...
متن کاملvoltammetric behavior and determination of isoniazid in pharmaceuticals by using silver oxyfluoride modified silver electrode
in the present study, silver oxyfluoride modified silver electrode was employed to electrocatalytic oxidation of isoniazid. the process of oxidation and its kinetics were established by using cyclic voltammetry, chronoamperometry and amperometry techniques. the modified electrode shows a stable and linear response in the concentration range of 3×10−4 to 2.1×10−3 mol l-1 with a correlation coeff...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Monatshefte für Chemie - Chemical Monthly
سال: 2019
ISSN: 0026-9247,1434-4475
DOI: 10.1007/s00706-018-2348-y