Quasi-static 3D structure of graphene ripple measured using aberration-corrected TEM
نویسندگان
چکیده
Our new method of measuring monolayer graphene revealed experimentally that the ripple structure was represented as a superposition sinusoidal waves, with their wave vectors coinciding specific direction six-membered ring.
منابع مشابه
Aberration corrected TEM: current status and future prospects
Aberration correction leads to a substantial improvement in the interpretable resolution of Transmission Electron Microscopes. Electron optical correctors based on two strong hexapole elements linked through a round lens transfer doublet enables direct correction of all axial aberrations to third order. Subsequent, indirect computational analysis of a focal or tilt series of images offers the p...
متن کاملAn Aberration Corrected (S)TEM Microscope for Nanoresearch
S. Kujawa, B. Freitag, D. Hubert FEI Company, Eindhoven, The Netherlands [email protected] Introduction The continued focus on improving materials, combined with the fact that it is now commonly understood that material properties are affected by characteristics at the atomic level, give rise to the need to characterize and image at the best resolutions possible. The (Scanning) Transmiss...
متن کاملAmplitude Contrast Imaging: High Resolution Electron Microscopy Using a Spherical and Chromatic Aberration Corrected TEM
High-resolution transmission electron microscopy (HREM) is a powerful technique to study materials at atomic resolution. For a conventional TEM, the Scherzer defocus is typically used to maximize phase contrast and resolution. For a TEM with a spherical aberration (Cs) image corrector, Jia et al introduced the negative Cs imaging (NCSI) method to balance the contrast and resolution [1]. This pa...
متن کاملPresent status and future prospects of spherical aberration corrected TEM/STEM for study of nanomaterials∗.
The present status of Cs-corrected TEM/STEM is described from the viewpoint of the observation of nanomaterials. Characteristic features in TEM and STEM are explained using the experimental data obtained by our group and other research groups. Cs correction up to the 3rd-order aberration of an objective lens has already been established and research interest is focused on correcting the 5th-ord...
متن کاملDouble aberration-corrected TEM/STEM of tungstated zirconia nanocatalysts for the synthesis of paracetamol
We report highly active tungstated zirconia nanocatalysts for the synthesis of paracetamol by Beckmann rearrangement of 4-hydroxyacetophenone oxime. Double aberration-corrected (2AC)-TEM/STEM studies were performed in a JEOL 2200FS FEG TEM/STEM at the 1 Angstrom (1 Å = 0.1 nanometer) level. Observations at close to zero defocus were carried out using the AC-TEM as well as AC-STEM including high...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Nanoscale
سال: 2021
ISSN: ['2040-3372', '2040-3364']
DOI: https://doi.org/10.1039/d1nr00237f