Quantitative assessment of three vendor’s metal artifact reduction techniques for CT imaging using a customized phantom
نویسندگان
چکیده
منابع مشابه
A New Method for Metal Artifact Reduction in CT Scan Images
Introduction In CT imaging, metallic implants inside the tissues cause metal artifact that reduce the quality of image for diagnosis. In order to reduce the effect of this artifact, a new method with more appropriate results has been presented in this research work. Materials and Methods The presented method comprised of following steps: a) image enhancement and metal areas extraction, b) sinog...
متن کاملAssessment of metal artifact reduction methods in pelvic CT.
PURPOSE Metal artifact reduction (MAR) produces images with improved quality potentially leading to confident and reliable clinical diagnosis and therapy planning. In this work, the authors evaluate the performance of five MAR techniques for the assessment of computed tomography images of patients with hip prostheses. METHODS Five MAR algorithms were evaluated using simulation and clinical st...
متن کاملsyngo WARP – Metal Artifact Reduction Techniques in Magnetic Resonance Imaging
■ Through-plane distortion: The local field offset leads to curved and frayed slices instead of the expected flat image plane (Fig. 1). Since both in-plane and through-plane distortions shift image pixels away from their real positions, image geometry appears to be distorted. In both cases, regions with severe field changes will lead to signal voids visible as black spots and signal pileups vis...
متن کاملMetal artifact reduction in CT using fusion based prior image.
PURPOSE In computed tomography, metallic objects in the scanning field create the so-called metal artifacts in the reconstructed images. Interpolation-based methods for metal artifact reduction (MAR) replace the metal-corrupted projection data with surrogate data obtained from interpolation using the surrounding uncorrupted sinogram information. Prior-based MAR methods further improve interpola...
متن کاملAssessment of EIT/CT Fusion Imaging using a Biological Phantom
A cylindrical slice of seeded winter melon with an air-cavity was imaged using CT and EIT imaging systems. The structural regions were extracted from the CT image using morphological image processing algorithms and fused with the functional information of its EIT image. Fusion performance showed a detectability increase of 67% along with a structural similarity increase of 26%.