Quantification of regional pulmonary blood flow using ASL-FAIRER
نویسندگان
چکیده
منابع مشابه
Quantification of regional pulmonary blood flow using ASL-FAIRER.
Pulsed arterial spin labeling (ASL) techniques have been theoretically and experimentally validated for cerebral blood flow (CBF) quantification. In this study ASL-FAIRER was used to measure regional pulmonary blood flow (rPBF) in seven healthy subjects. Two general ASL strategies were investigated: 1) a single-subtraction approach using one tag-control pair acquisition at an inversion time (TI...
متن کاملRegional Pulmonary Blood Flow
unteers were studied, nine sitting and seven supine. During hypoxia there was a slight but significant increase in relative perfusion of the upper portions of the lungs in both the sitting and supine subjects. During recovery from hypoxia, blood flow distribution differed significantly from the control. The erect subjects showed increased relative perfusion of the lung bases and the supine subj...
متن کاملAssessment of regional pulmonary blood flow using 68Ga-DOTA PET
BACKGROUND In vivo determination of regional pulmonary blood flow (PBF) is a valuable tool for the evaluation of many lung diseases. In this study, the use of 68Ga-DOTA PET for the in vivo quantitative determination of regional PBF is proposed. This methodology was implemented and tested in healthy pigs and validated using fluorescent microspheres. The study was performed on young large white p...
متن کاملQuantification of regional myocardial blood flow in vivo with H215O.
Using H215O (half-life = 2.1 min) we demonstrated that a modification of the tissue autoradiographic approach permitted quantitation of myocardial blood flow in open-chest dogs by direct assay of myocardial tissue and that noninvasive estimation with positron-emission tomography (PET) delineated relative myocardial blood flow in intact dogs. In open-chest anesthetized dogs, the single-pass extr...
متن کاملQuantification of Regional Myocardial Blood Flow by Microspheres
Background. Both ['3N ammonia and ['5Olwater have been used to quantify myocardial blood flow with positron emission tomography using appropriate tracer kinetic models. A direct comparison of the two tracers with radioactive microspheres has not been performed in the same experimental preparation. Methods and Results. The two tracers have been tested for myocardial blood flow quantification in ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Magnetic Resonance in Medicine
سال: 2006
ISSN: 0740-3194,1522-2594
DOI: 10.1002/mrm.20891