Pyriform Sinus Localization-Assisted Blind Intubation: Comparison with Laryngoscopic Intubation
نویسندگان
چکیده
منابع مشابه
Pyriform Sinus Localization-Assisted Blind Intubation: Comparison with Laryngoscopic Intubation
BACKGROUND Conventional endotracheal intubation requires laryngoscopy for a direct view of the glottis. However, laryngoscopy is associated with many potential complications. The aim of the present study was to compare the efficacy and safety of pyriform sinus localization-assisted blind orotracheal intubation with those of conventional laryngoscopic orotracheal intubation. MATERIAL AND METHO...
متن کاملEmergency tracheal intubation: complications associated with repeated laryngoscopic attempts.
Repeated conventional tracheal intubation attempts may contribute to patient morbidity. Critically-ill patients (n = 2833) suffering from cardiovascular, pulmonary, metabolic, neurologic, or trauma-related deterioration were entered into an emergency intubation quality improvement database. This practice analysis was evaluated for airway and hemodynamic-related complications based on a set of d...
متن کاملBlind nasal intubation with propanidid.
Sir,—Dr Collier is disappointed that we did not comment on e.c.g. changes during hypotension. Alas, we cannot remedy this because no such changes occurred. A continuous recording was taken in each case and none showed any arrhythmia. If she has evidence that changes in rhythm during hypotension indicate cardiac hypoxia and a low cardiac output (and "considered by some" hardly rates as evidence)...
متن کاملComparison of efficiency between i-gel blind intubation and i-gel-assisted bronchoscopic intubation during cardiopulmonary resuscitation: randomized simulation study
Results The mean intubation time using IGI was shorter (p < 0.017) than that of IBRI and MCL in both endotracheal tubes (17.6 vs. 29.3 vs. 20.2 in conventional PVC tube; 14.6 vs. 27.4 vs. 19.9 in wire-reinforced silicone tube; sec). There were no significant (p > 0.05) differences between conventional PVC and wire-reinforced silicone tube for each intubation technique. The cumulative success ra...
متن کاملComparison of bougie-assisted intubation with traditional endotracheal intubation in a simulated difficult airway.
OBJECTIVE To compare the success and ease of bougie-assisted intubation (BAI) with those of traditional endotracheal intubation (ETI) in a simulated difficult airway (20.4 seconds for BAI vs. 16.7 seconds for ETI, p = 0.102). METHODS This was a prospective, randomized, crossover, single-blind study comparing BAI with ETI in a simulated difficult airway. The 35 participants included paramedics...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Medical Science Monitor
سال: 2014
ISSN: 1643-3750
DOI: 10.12659/msm.892195