PVC-membrane potentiometric sensors based on a recently synthesized Schiff base for Fe(III) ion
نویسندگان
چکیده
منابع مشابه
PVC Membrane Sensors for Potentiometric Determination of Acebutolol
The construction and general performance characteristics of two novelpotentiometric membrane sensors responsive to the acebutolol are described. Thesensors are based on the use of ion-association complexes of acebutolol (AC) withtetraphenylborate(TPB) (I) and phosphomolybdate(PM) (II) as exchange sites in a PVCmatrix. The sensors show a fast, stable and near- Nernstian for the mono charge catio...
متن کاملClomipramine Determination by Potentiometric PVC Membrane and Carbon Paste Sensors
Clomipramine hydrochloride, active component of an antidepressant drug, was determined in the pharmaceutical formulation by two kinds of potentiometric sensor; a PVC membrane sensor and a carbon paste electrode modified by MWCNTs and ionic liquid. Both sensors were corporated with clomipramine-tetraphenylborate ion-pair complex and they respond based on ion exchange mechanism. The best PVC memb...
متن کاملHighly Selective Perchlorate Membrane Electrode Based on Synthesized Schiff Base Complex
In this work we introduce a practical use of synthesized Schiff base metal complex in sensing application. A new perchlorate-selective electrode based on the complex N, N'-4-nitro-phenylmethanebis-(salicylaldiminato) copper (II) [CuL] as the membrane carrier was developed. The electrode exhibits a good Nernstian slope of -55.0 ± 1.0 mV/decade and a linear range of for perchlorate. The lim...
متن کاملSilver ion recognition using potentiometric sensor based on recently synthesized isoquinoline-1,3-dione derivatives
The four derivatives of isoquinoline-1,3-dione based on β-lactum (I-IV), have been explored as neutral ionophores for preparing poly(vinylchloride) based polymeric membrane electrodes (PME) selective to silver(I) ions. The addition of sodium tetraphenylborate (NaTPB) and dioctylsebacate (DOS) as a plasticizer was found to improve the performance of ion selective electrodes. The best performance...
متن کاملPolymer membrane-based ion-, gas- and bio-selective potentiometric sensors.
Recent progress in the design of new polymer membrane-based potentiometric ion-, gas- and bio-selective electrodes in chemistry laboratories at the University of Michigan (Ann Arbor) is reviewed. Emphasis is placed on describing the performance of devices for measuring anions (e.g., salicylate, thiocyanate, chloride and heparin) and gases (e.g., ammonia, carbon dioxide and oxygen) in biological...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Bulletin of the Chemical Society of Ethiopia
سال: 2012
ISSN: 1011-3924
DOI: 10.4314/bcse.v26i1.7