Pushover Analysis of Slip formed Load Bearing Wall Panels
نویسندگان
چکیده
منابع مشابه
Connections for Precast Concrete Load-bearing Shear Wall Panels
Precast load-bearing shear wall panels are used extensively for high-rise construction because of the ease and speed of assembly, and the high quality of the precast panels. The connections between panels are extremely important since they affect both the speed of erection '~md the overall integrity of the structure. This paper presents the results of a four-year research program conducted to i...
متن کاملHorizontal Post - Tensioned Connections for I ' Recast Concrete Load - Bearing Shear Wall Panels
Precast load-bearing shear wall panels are used extensively for high-rise construction because of the ease and speed of assembly, and the high quality of the precast panels. The connections between panels are extremely important since they affect both the speed of erection and the overall integrity of the structure. This paper presents the results of a research program conducted to investigate ...
متن کاملPushover analysis of multi-storey cantilever wall systems
Midto high-rise buildings are often braced by slender reinforced concrete (RC) walls, which are coupled by RC floor diaphragms. In design it is typically assumed that the walls act independently and the design base shear demand is computed neglecting any compatibility forces between the walls. Pushover analysis of systems comprising walls of different lengths have, however, shown that large com...
متن کاملPerformance of Infilled Profiled Steel Sheet Dry Board PSSDB Load Bearing Wall (TECHNICAL NOTE)
This paper describes the testing of Profiled Steel Sheet Dry Board (PSSDB) load bearing wall system. Experimental tests were conducted on various PSSDB wall samples, with and without infill materials to study its effect on the PSSDB load bearing wall performance. A proprietary profiled steel sheet, Ajiya Cliplock (0.48 mm thick) attached to Cemboard (10 mm thick) on one side, and Cemplank (10 m...
متن کاملProposal of lateral load pattern for pushover analysis of RC buildings
The proposal lateral load pattern for pushover analysis is given in two forms for symmetric concrete buildings: 1-(X/H)0.5 for low-rise and mid-rise buildings, 2- Sin(ΠX/H) for high-rise buildings. These two forms give more realistic results as compared to conventional load patterns such as triangular and uniform load patterns. The assumed buildings of 4, 8, 12, 16, 20 and 30 story concrete bui...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Engineer: Journal of the Institution of Engineers, Sri Lanka
سال: 2007
ISSN: 2550-3219,1800-1122
DOI: 10.4038/engineer.v40i4.7151