“Pulse Oximetryin Pulp Vitality Test – Comparative Evaluation with the Conventional Techniques

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of efficacy of a pulse oximeter to assess pulp vitality.

BACKGROUND To evaluate the efficacy of pulse oximeter as a pulp vitality tester. MATERIALS AND METHODS The sample group consisted of 60 patients of age 15 to 30 years with normal maxillary anterior teeth. Thirty nonvital teeth with complete endodontic fillings were tested as control group. Systemic oxygen saturation values from the patient's fingers served as the control sample for comparison...

متن کامل

Comparative Study of Pulp Vitality in Primary and Young Permanent Molars in Human Children with Pulse Oximeter and Electric Pulp Tester

AIM AND OBJECTIVE The purpose of this study was to compare the pulp testing methods (pulse oximetry and electric pulp test) in primary and young permanent teeth of children. MATERIALS AND METHODS The study included a total of 155 children aged 4 to 15 years. Twenty children formed control group I. Study group included all healthy, 85 primary 2nd molars in group II and 85 permanent 1st molars ...

متن کامل

Development and initial testing of a pulse oximetry prototype for measuring dental pulp vitality

The guiding principle of endodontic treatment is to preserve teeth while maintaining its aesthetic and functional roles. To accomplish this goal the assessment of teeth pulp vitality is very important since it will determine the procedures that should be adopted and define the therapy strategy. Currently, the most commonly tests for determining dental pulp state are the thermal and the electric...

متن کامل

Assessment of pulp vitality: a review.

BACKGROUND One of the greatest diagnostic challenges in clinical practice is the accurate assessment of pulp status. This may be further complicated in paediatric dentistry where the practitioner is faced with a developing dentition, traumatized teeth, or young children who have a limited ability to recall a pain history for the tooth in question. A variety of pulp testing approaches exist, and...

متن کامل

Evaluation of the ability of thermal and electrical tests to register pulp vitality.

The aim of the present study was to evaluate the ability of thermal and electrical tests to register pulp vitality. Sensitivity, specificity, negative predictive value and positive predictive value were calculated by comparing the test results with a "gold standard". The thermal tests studied were a cold test (ethyl chloride) and a heat test (hot gutta-percha). For the electrical test, the Anal...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IOSR Journal of Dental and Medical Sciences

سال: 2016

ISSN: 2279-0861,2279-0853

DOI: 10.9790/0853-150761016