Prevention of Distal Embolization During Peripheral Vascular Interventions
نویسندگان
چکیده
منابع مشابه
Distal Embolization in Femoropopliteal Interventions
D istal embolization (DE) occurs frequently during femoropopliteal (FP) interventions. Treatment of FP atherosclerotic lesions with balloon angioplasty, stenting, atherectomy, embolectomy, or catheter-directed lysis is likely to yield significant debris.1-11 Despite a high rate of DE reaching 100% in some reports,3,10 data suggest that only 2% to 3% of patients will eventually require additiona...
متن کاملMechanical prevention of distal embolization during primary angioplasty: safety, feasibility, and impact on myocardial reperfusion.
BACKGROUND Effective myocardial reperfusion after primary percutaneous coronary intervention (PCI) may be limited by distal embolization. We tested the safety, feasibility, and efficacy of the FilterWire-Ex (FW), a distal embolic protection device, as an adjunct to primary PCI. METHODS AND RESULTS Fifty-three consecutive patients undergoing primary PCI with FW protection were compared with a ...
متن کاملPrevention of Distal Embolization During Coronary Angioplasty in Saphenous Vein Grafts
Eberhard Grube, Ulrich Gerckens, Alan C. Yeung, Sascha Rowold, Nicole Kirchhof, Jerry and Native Vessels Using Porous Filter Protection Prevention of Distal Embolization During Coronary Angioplasty in Saphenous Vein Grafts Print ISSN: 0009-7322. Online ISSN: 1524-4539 Copyright © 2001 American Heart Association, Inc. All rights reserved. is published by the American Heart Association, 7272 Gree...
متن کاملPrevention of distal embolization during saphenous vein graft lesion angioplasty. Experience with a new temporary occlusion and aspiration system.
BACKGROUND Repeat coronary artery bypass graft surgery (CABG) is associated with a high morbidity and mortality, rendering percutaneous treatment of saphenous vein graft (SVG) lesions an attractive alternative. However, percutaneous interventions of degenerated SVGs carries high risk of distal embolization. METHODS AND RESULTS This study reports our initial experience with the PercuSurge Guar...
متن کاملPrevention of distal embolization during coronary angioplasty in saphenous vein grafts and native vessels using porous filter protection.
BACKGROUND Although distal embolization and the "no-reflow" phenomenon are well described in saphenous vein graft (SVG) interventions, the frequency, magnitude, and characterization of embolized debris have not been evaluated in routine coronary interventions. A unique embolus protection device described herein provides a means of containing and retrieving plaque material dislodged during percu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: JACC: Cardiovascular Interventions
سال: 2017
ISSN: 1936-8798