Experimental Study on the Effect of Heat Loads, Fill Ratio and Extra Volume on Performance of a Partial-Vacuumed Thermosyphon
This paper reports a study on the effect of the heat flux, cooling water flow rate, fill ratio and extra volume on the overall performance of a partially vacuumed <span style="font-size: 10pt; color: #...
متن کاملExperimental Investigation on Hydrodynamic and Thermal Performance of a Gas-Liquid Thermosyphon Heat Exchanger in a Pilot Plant
Waste heat recovery is very important, because not only it reduces the expenditure of heat generation, but also it is of high priority in environmental consideration, such as reduction in greenhouse gases. One of the devices is used in waste heat recovery is heat pipe heat exchanger.Anexperimental research has been carried out to investigate the hydrodynamic and thermal performance of a gas...
متن کاملDiffusion Induced Chaos in a Closed Loop Thermosyphon
The dynamics of a closed loop thermosyphon are considered. The model assumes a prescribed heat flux along the loop wall and the contribution of axial diffusion. The well-posedness of the model which consists of a coupled ODE and PDE is shown for both the case with diffusion and without diffusion. Boundedness of solutions, the existence of an attractor, and an inertial manifold is proven, and an...
متن کاملExperimental Investigation of Boiling and Condensation Heat Transfer of a two Phase Closed Thermosyphon
In this paper the heat transfer characteristics of a two-phase closed thermosyphon over a wide range of heat transfer rates, system pressure, aspect ratios and filling ratios were studied. The experiments focused on the boiling and condensation heat transfer characteristics of the thermosyphon. The experimental boiling and condensation heat transfer coefficients inside the thermosyphon were com...
متن کاملExperimental Investigations on the Thermal Performance of a Vertical Closed Loop Pulsating Heat Pipe Using Binary Mixture of Fluids
This paper presents the experimental investigations conducted on a vertical closed loop pulsating heat pipe (VCLPHP) to evaluate the thermal performance. The values of thermal resistance and heat transfer coefficient obtained in the experimentation is used as evaluation parameters. The VCLPHP used has capillary tubes having an inner diameter of 2mm and outside diameter 3mm and bent into 5 turns...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Recent Advances in Petrochemical Science
سال: 2018
ISSN: 2575-8578
DOI: 10.19080/rapsci.2018.05.555672