Predicting glare from daylight through microstructures solar control systems using matrix-based simulation methods in Radiance
نویسندگان
چکیده
In this study the five-phase method and a parallelized invocation of evalglare has been used, to evaluate performance microstructure Low-E window w/wo external blind, in terms glare. The first part results investigates how Bidirectional-Scattering-Distribution-Functions, BSDF, aBSDF (Aperture BSDF) properties bias predicted glare through microstructure, linking BSDF rank saturation resolution contrast investigation found combination correct rank, low peak extraction (aBSDF) be best trade-off between speed accuracy. later comparison none investigated systems sufficient protection. was outperform blinds, using current shading schedule (9% difference occupied hours exceeding DGP 0.45).
منابع مشابه
An Approach to Predict Daylight Glare Using Nazzal’s Daylight Glare Index Formula
One of the important functions of window is to admit natural lightto interior spaces of buildings. This natural lighting in buildings helps to displace the requirement for artificial lighting, and thus, helps to save energy. Though daylight has positive effects on visual comfort, but high window luminance or direct sunlight from a window may cause discomfort. Visual discomfort in a day-lit inte...
متن کاملDynamic Daylight Glare Evaluation
In non-residential buildings, comfort and energy demand for heating, cooling and lighting are significantly influenced by the façade. Up to now, only non-weighted luminance-based methods for calculating and evaluating annual daylight glare exist (Lee et al., 2005; Mardaljevic and Lomas., 1998). Within this paper, different methods based on the daylight glare probability DGP (Wienold and Christo...
متن کاملDaylight Design of Office Buildings: Optimisation of External Solar Shadings by Using Combined Simulation Methods
Integrating daylight and energy performance with optimization into the design process has always been a challenge for designers. Most of the building environmental performance simulation tools require a considerable amount of time and iterations for achieving accurate results. Moreover the combination of daylight and energy performances has always been an issue, as different software packages a...
متن کاملValidation of Gpu Lighting Simulation in Naturally and Artificially Lit Spaces
Daylight in buildings is both aesthetically pleasing and a sustainable means of offsetting costs for space conditioning and electric lighting. However, poor use of daylight can cause glare that impedes worker productivity. Traditional means of predicting lighting levels for indoor spaces through simulation are timeconsuming, which inhibits exploration of daylighting potential in new buildings. ...
متن کاملEvaluating the Effectiveness of Daylight Performance Metrics in Predicting Visual Comfort Case Study: Educational Architecture Design Studios in Tehran
It is essential to ensure that adequate daylight penetrates in, especially, educational environments. In spite of positive significant impacts of daylight on the emotions, concentration, and learning of students, an exceeded amount of light will lead to glare and visual dissatisfaction. Over the last few years, with the help of simulation tools and lighting indices, it is possible to predict li...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: E3S web of conferences
سال: 2022
ISSN: ['2555-0403', '2267-1242']
DOI: https://doi.org/10.1051/e3sconf/202236208002