Power Transformers and Environmental Protection
نویسندگان
چکیده
منابع مشابه
A Novel Flux-Based Protection Scheme for Power Transformers
Internal Turn-Turn faults (TTF) are the most common failures in power transformers, which could seriously reduce their life expectancy. Although common protection schemes such as current-baseddifferential protection are able to detect some of the internal faults, some other minor ones (such as TTFs andshort circuit near the neutral point) cannot be detected by such schemes. Likewise, these rela...
متن کاملPower Transformers Differential Protection Using the p-q Power Theory
This paper describes the application of the p-q power theory to the differential protection of power transformers. The information provided by the harmonic content of the differential active and reactive power components is used to detect winding insulation failures and to distinguish them from magnetizing inrush current transients. A variety of test cases is presented in the paper, demonstrati...
متن کاملa novel flux-based protection scheme for power transformers
internal turn-turn faults (ttf) are the most common failures in power transformers, which could seriously reduce their life expectancy. although common protection schemes such as current-baseddifferential protection are able to detect some of the internal faults, some other minor ones (such as ttfs andshort circuit near the neutral point) cannot be detected by such schemes. likewise, these rela...
متن کاملDifferential Protection for Arbitrary Three-Phase Power Transformers
This thesis describes how to provide standardized, current based, differential protection for any three-phase power transformer, including phase-shifting transformers with variable phase angle shift and transformers of all construction types and internal on-load tap-changer configurations. The use of standard transformer differential protection for such applications is considered impossible in ...
متن کاملProtection of Power Transformers Against Geomagnetically Induced Currents
The article examines the problem of saturation and failure of power transformers under geomagnetically induced currents and currents of the E3 component of high-altitude nuclear explosions. It also describes a special protective relay reacting on DC component in the transformer neutral current.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IFAC-PapersOnLine
سال: 2016
ISSN: 2405-8963
DOI: 10.1016/j.ifacol.2016.10.693