Potentiometry at Trace Levels in Confined Samples: Ion-Selective Electrodes with Subfemtomole Detection Limits

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of sodium with ion-selective electrodes.

The advent of ion-selective electrodes made possible the potentiometry of sodium in serum and plasma. These methods were based on dilution of serum, as done in flame photometry, and the results were identical. Analysis of whole blood precludes dilution and so "direct" potentiometry was developed. Results by this technique are variable but tend to compensate for the spurious hyponatremias found ...

متن کامل

Bicarbonate interference with chloride-ion-selective electrodes.

echocardiography. All attending phy-sicians/cardiologists were blinded to the BNP results. To determine the diagnostic accuracy of the two assays for CHF, we performed ROC plot analysis, and areas under the curve (AUC) were calculated for both BNP assays. Comparisons between AUC were assessed according to the method of Hanley and McNeil (10). Cutoff values for the two methods were determined at...

متن کامل

Applications of Ion Selective Electrodes

Enzyme sensor for organophosphorus insecticides organophosphorus hydrolase in a polymer membrane on a pH sensor is used to catalyse the hydrolysis of compounds with phoshate ester functionality. The detected [H+] change is proportional to the concentration of the phosphate ester insecticide. This is a good example of the use of an enzyme to give selectivity to a specific class of compounds. Unf...

متن کامل

Ion Activity Scales for Use with Selective Ion-sensitive Electrodes

The development of a variety of selective ion-sensitive electrodes focuses attention on numerical scales for the activity of individual ionic species, for these electrodes measure the activity of the selected ion only relative to that of the same species in a reference solution of known or assigned ion activity. Nevertheless, scales of ion activity must be based on a convention from outside the...

متن کامل

Solid-contact potentiometric polymer membrane microelectrodes for the detection of silver ions at the femtomole level.

In recent years, ion-selective electrodes based on polymer membranes have been shown to exhibit detection limits that are often in the nanomolar concentration range, and thus drastically lower than traditionally accepted. Since potentiometry is less dependent on scaling laws that other established analytical techniques, their performance in confined sample volumes is explored here. Solid-contac...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Journal of the American Chemical Society

سال: 2006

ISSN: 0002-7863,1520-5126

DOI: 10.1021/ja0625780