POTENTIOMETRIC IMMUNOSENSOR BASED ON PHOTOSENSITIVE PVC/SPIROBENZOPYRAN MEMBRANE
نویسندگان
چکیده
منابع مشابه
Potentiometric enzyme channeling immunosensor for proteins.
A potentiometric immunosensor for the detection of human IgG has been developed using an asymmetric, ion-selective membrane with immobilized adenosine deaminase and IgG. A protein A-alkaline phosphatase conjugate binds to the immobilized IgG, creating a bienzymatic catalytic layer. In the presence of sample IgG, the conjugate does not bind to the membrane. Instead, the intermediate in the two-s...
متن کاملPotentiometric Based Membrane Sensor for Zinc Ion
A PVC-based membrane of 12-crown-4 exhibits good response for Zn2+ in a wide concentration range (7.08 10-5-1.00 10-1 M) with a non-nernstian slope of 20.5 mv per decade of concentration of Zn2+. The response time of sensor is <10 s and the membrane can be used for more than 3 months without observing any divergence. In addition, the proposed sensor exhibits very good selectivity for Zn2+ o...
متن کاملNovel ibuprofen potentiometric membrane sensors based on tetraphenylporphyrinato indium(III).
Two novel potentiometric membrane sensors responsive to the ibuprofen drug have been developed. These incorporate poly(vinyl chloride) and polyurethane matrix membranes containing 5,10,15,20-tetraphenylporphrinato (TPP) indium(II) ionophore plasticized with dibutylsebacate. The sensors show a near-Nernstian response with anionic slopes of -53 and -55 mV decade(-1), over the concentration range ...
متن کاملPolymer membrane-based ion-, gas- and bio-selective potentiometric sensors.
Recent progress in the design of new polymer membrane-based potentiometric ion-, gas- and bio-selective electrodes in chemistry laboratories at the University of Michigan (Ann Arbor) is reviewed. Emphasis is placed on describing the performance of devices for measuring anions (e.g., salicylate, thiocyanate, chloride and heparin) and gases (e.g., ammonia, carbon dioxide and oxygen) in biological...
متن کاملChemiluminescent immunosensor for CA19-9 based on antigen immobilization on a cross-linked chitosan membrane.
A novel chemiluminescent immunosensor for carbohydrate antigen 19-9 (CA19-9) based on the immobilization of CA19-9 on the cross-linked chitosan membrane was developed. The different membranes were characterized by atomic force microscopy (AFM) and infrared spectrum, respectively. Based on a noncompetitive immunoassay format, this proposed chemiluminescent immunosensor enabled a low-cost, flexib...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Analytical Sciences
سال: 1991
ISSN: 0910-6340,1348-2246
DOI: 10.2116/analsci.7.supple_883