Potassium Ion Current in the Squid Giant Axon
نویسندگان
چکیده
منابع مشابه
Ammonium Ion Currents in the Squid Giant Axon
Voltage-clamp studies on intact and internally perfused squid giant axons demonstrate that ammonium can substitute partially for either sodium or potassium. Ammonium carries the early transient current with 0.3 times the permeability of sodium and it carries the delayed current with 0.3 times the potassium permeability. The conductance changes observed in voltage clamp show approximately the sa...
متن کاملKinetics of Ion Movement in the Squid Giant Axon
The loss of Na(22), K(42), and Cl(36) from single giant axons of the squid, Loligo pealii, following exposure to an artificial sea water containing these radioisotopes, occurs in two stages, an initial rapid one followed by an exponential decline. The time constants of the latter stage for the 3 ion species are, respectively, 290, 200, and 175 minutes. The outflux of sodium is depressed while t...
متن کاملPotassium conductance of the squid giant axon. Single-channel studies
The patch-clamp technique was implemented in the cut-open squid giant axon and used to record single K channels. We present evidence for the existence of three distinct types of channel activities. In patches that contained three to eight channels, ensemble fluctuation analysis was performed to obtain an estimate of 17.4 pS for the single-channel conductance. Averaged currents obtained from the...
متن کاملThe actions of some general anaesthetics on the potassium current of the squid giant axon.
A number of small organic molecules with general anaesthetic action have been examined for their effects on the voltage-dependent potassium current of the squid giant axon. They include representatives of the three classes of anaesthetics examined in previous studies on the sodium current (Haydon & Urban, 1983a, b, c), i.e. the non-polar molecules n-pentane, cyclopentane and CCl4, several n-alk...
متن کاملIonic Current Measurements in the Squid Giant Axon Membrane
The concepts, experiments, and interpretations of ionic current measurements after a step change of the squid axon membrane potential require the potential to be constant for the duration and the membrane area measured. An experimental approach to this ideal has been developed. Electrometer, operational, and control amplifiers produce the step potential between internal micropipette and externa...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Biophysical Journal
سال: 1960
ISSN: 0006-3495
DOI: 10.1016/s0006-3495(60)86871-3