Post-Earthquake Damage Identification of Buildings with LMSST
نویسندگان
چکیده
The structure is said to be damaged if there a permanent shift in the post-event natural frequency of as compared with pre-event frequency. To assess damage structure, time-frequency approach that can capture and required. In this study, determine these frequencies, local maximum synchrosqueezing transform (LMSST) method employed. Through simulation results, we have shown traditional methods such Wigner distribution, Wigner–Ville distributions, pseudo-Wigner–Ville smoothed transforms are not capable capturing structure. amplitude signal captured by sensors during those events very small seismic event. Thus, cannot post-event, whereas LMSST employed work easily identify frequencies. This attribute makes it attractive for post-earthquake detection. claims qualitatively quantitatively substantiated comprehensive numerical analysis.
منابع مشابه
Examination of reasons of variance in earthquake damage rates in earthen buildings of the historic village of Esfahak post Tabas earthquake
Earthen building materials have been in common use as cheap, available, and practical construction materials in hot and dry areas for a long time. Earthen buildings exist in Iran, especially in villages, because of the large and numerous areas that have the same climate. Given that Iran is highly earthquake prone and the importance of paying attention to the possible vulnerability of all the in...
متن کاملExamination of reasons of variance in earthquake damage rates in earthen buildings of the historic village of Esfahak post Tabas earthquake
Earthen building materials have been in common use as cheap, available, and practical construction materials in hot and dry areas for a long time. Earthen buildings exist in Iran, especially in villages, because of the large and numerous areas that have the same climate. Given that Iran is highly earthquake prone and the importance of paying attention to the possible vulnerability of all the in...
متن کاملPost-Earthquake Damage Inspection of Wood-Frame Buildings by a Polarimetric GB-SAR System
Structural damage inspection after an earthquake is essential for safety assessment of the affected wood-frame buildings and for making knowledgeable decision regarding their repair, renovation, or replacement. We present a polarimetric radar system for sensing the concealed wood-frames damaged by earthquakes. This system employs an antenna array consisting of four linearly polarized Vivaldi an...
متن کاملStudy on Earthquake Damage Distribution of Multistory Masonry Buildings
The main components which affect the earthquake damage grades classification of multistory masonry buildings and the damage characters are summarized and analyzed through the statistics and analysis of a large number of previous earthquake damage data. According to the standard of earthquake damage grades classification, the damage numbers of each component of multistory masonry buildings under...
متن کاملBuilding Damage Detection from Post-earthquake
The collapsed buildings due to earthquake were detected from post-event aerial images using watershed segmentation algorithm. The objective was to detect the collapsed buildings based on the analysis of the cast shadows. The building boundaries were available and stored in a GIS as vector polygons. The building polygons were utilized to perform assessments in a building specific manner. The app...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Buildings
سال: 2023
ISSN: ['2075-5309']
DOI: https://doi.org/10.3390/buildings13071614