Polarization control in a crossed undulator without a monochromator

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

SASE FEL Polarization Control Using Crossed Undulator∗

There is a growing interest in producing intense, coherent x-ray radiation with an adjustable and arbitrary polarization state. In this paper, we study the crossed undulator scheme for rapid polarization control in a self-amplified spontaneous emission (SASE) free electron laser (FEL). Because a SASE source is a temporally chaotic light, we perform a statistical analysis on the state of polariz...

متن کامل

Polarization Analysis of Nonlinear Harmonic Radiation in a Crossed-Planar Undulator

There is growing interest in producing intense, coherent x-ray radiation with an adjustable and arbitrary polarization state. The crossed-planar undulator, which was first proposed by Kim, could achieve rapid polarization control in synchrotron radiation sources and free electron lasers (FELs) through the manipulation of a phase shifter. Recently, a statistical analysis shows that a polarizatio...

متن کامل

A crossed brain stem syndrome without crossed sensory symptomatology.

Lateral medullary infarction (LMI) or Wallenberg syndrome is a type of brain stem stroke, more specifically, a type of crossed brain stem syndrome. LMI is a well-described entity with several documented typical characteristics including pain and temperature impairment in the ipsilateral to the lesion side of the face and the contralateral side of the trunk and limbs. We present a case of LMI wh...

متن کامل

Polarization control using passive and active crossed graphene gratings.

Graphene gratings provide a promising route towards the miniaturization of THz metasurfaces and other photonic devices, chiefly due to remarkable optical properties of graphene. In this paper, we propose novel graphene nanostructures for passive and active control of the polarization state of THz waves. The proposed devices are composed of two crossed graphene gratings separated by an insulator...

متن کامل

Rotation of X-ray polarization in the glitches of a silicon crystal monochromator

EXAFS studies on dilute samples are usually carried out by collecting the fluorescence yield using a large-area multi-element detector. This method is susceptible to the 'glitches' produced by all single-crystal monochromators. Glitches are sharp dips or spikes in the diffracted intensity at specific crystal orientations. If incorrectly compensated, they degrade the spectroscopic data. Normaliz...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: New Journal of Physics

سال: 2020

ISSN: 1367-2630

DOI: 10.1088/1367-2630/aba730