PO-0899 Validation of dose calculation accuracy on daily cone-beam CT scans in the thoracic region

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Shading correction for cone-beam CT in radiotherapy: Validation of dose calculation accuracy using clinical images

Cone-beam CT (CBCT) images are routinely acquired to verify patient position in radiotherapy (RT), but are typically not calibrated in Hounsfield Units (HU) and feature non-uniformity due to X-ray scatter and detector persistence effects. This prevents direct use of CBCT for re-calculation of RT delivered dose. We previously developed a prior-image based correction method to restore HU values a...

متن کامل

Correction of megavoltage cone‐beam CT images of the pelvic region based on phantom measurements for dose calculation purposes

Megavoltage cone-beam CT (MVCBCT) is an imaging technology that provides a 3D representation of the patient in treatment position. Because it is a form of x-ray tomography, MVCBCT images give information about the attenuation coefficients of the imaged tissues, and thus could be used for dose calculation. However, the cupping and missing data artifacts seen on MVCBCT images can cause inaccuraci...

متن کامل

Accuracy of reconstructed images from cone-beam computed tomography scans.

INTRODUCTION The aim of this study was to determine whether 2-dimensional (2D) images produced from cone-beam computed tomography (CBCT) images taken with an iCAT scanner (Imaging Sciences International, Hatfield, Pa) can substitute for traditional cephalograms. METHODS Lateral and frontal cephalograms were taken of a radiographic phantom with known dimensions. Landmarks on the 2D images were...

متن کامل

SU-E-I-06: Measurement of Skin Dose from Dental Cone-Beam CT Scans.

PURPOSE To directly measure skin dose using point-dosimeters from dental cone-beam CT (CBCT) scans. To compare the results among three different dental CBCT scanners and compare the CBCT results with those from a conventional panoramic and cephalomic dental imaging system. METHODS A head anthropomorphic phantom was used with nanoDOT dosimeters attached to specified anatomic landmarks of selec...

متن کامل

SU-E-T-520: Quantitative Evaluation of Metal Artifacts in CT and Cone-Beam CT Images on the Accuracy of Dose Calculation.

PURPOSE To investigate effects of metal artifacts on the dose calculation accuracy of three dose calculation algorithms on CT and cone-beam CT images. METHODS A phantom with and without metal objects was scanned using CT simulator and on-board kV CBCT. Conformal 5-field treatment plans with identical physical and dosimetric parameters were created in the Eclipse™ treatment planning system for...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Radiotherapy and Oncology

سال: 2019

ISSN: 0167-8140

DOI: 10.1016/s0167-8140(19)31319-2