PIXEL-BASED CORRECTION METHOD FOR GAFCHROMIC®EBT FILM DOSIMETRY
نویسندگان
چکیده
منابع مشابه
Pixel-based Correction Method for Gafchromicebt Film Dosimetry
HAE SUN JEONG, YOUNGYIH HAN, OYEON KUM, CHAN HYEONG KIM, SANG GYU JU, JUNG SUK SHIN, JIN SUNG KIM, and JOO HWAN PARK Department of Nuclear Engineering, Hanyang University 17 Haengdang, Seongdong, Seoul 133-791, Korea Korea Atomic Energy Research Institute 1045 Daedoek-daero, Yuseong-gu, Daejeon 305-353, Korea Department of Radiation Oncology, Samsung Medical Center, Sungkyunkwan University Scho...
متن کاملEvaluation of triple channel correction acquisition method for radiochromic film dosimetry
The purpose of this study was to evaluate the triple channel correction acquisition (TCCA) method for radiochromic film dosimetry performed with a flatbed scanner. The study had two parts: a fundamental and a clinical examination. In the fundamental examination, we evaluated the accuracy of calibration curves for Gafchromic EBT2 (EBT2). The films were calibrated using a field-by-field method wi...
متن کاملPixel response‐based EPID dosimetry for patient specific QA
Increasing use of high dose rate, flattening filter free (FFF), and/or small-sized field beams presents a significant challenge to the medical physics community. In this work, we develop a strategy of using a high spatial resolution and high frame rate amorphous silicon flat panel electronic portal imaging device (EPID) for dosimetric measurements of these challenging cases, as well as for conv...
متن کاملRadiochromic Film Dosimetry
Published by the American Association of Physicists in Medicine DISCLAIMER: This publication is based on sources and information believed to be reliable, but the AAPM and the editors disclaim any warranty or liability based on or relating to the contents of this publication. The AAPM does not endorse any products, manufacturers, or suppliers. Nothing in this publication should be interpreted as...
متن کاملFilm Badge Dosimetry Versus Luminescence Dosimetry
The field of personnel radiation monitoring is presently in a state of radical change. It appears that the unreliability of the film badge is now firmly established, bringing into question the value of much of the massive amount of personnel dosimetry data accumulated in the past three decades. This article examines the evidence "against" the film badge and reviews the comparative studies "for"...