Peri-implant strain with locator and bar attachment during dislodging of maxillary implant overdenture. A comparative invitro study
نویسندگان
چکیده
Purpose: This study aimed to evaluate Peri-implant strain with locator and bar attachment during dislodging of maxillary implant overdenture Materials methods: Four implants were inserted in completely edentulous acrylic model canine premolar areas. Experimental overdentures 4 metal hooks constructed connected the attachments (group I) or 2). Two gauges bonded at buccal palatal surface each implant. Micro strains measured vertical overdenture. Dislodging was made by chains one end a universal testing machine other end. Results: For implants, showed significant higher microstrain values than gauge positions. group, no difference between positions detected. However, for attachments, demonstrated gauges. gauges, both groups Conclusion: Within limitation this vitro study, could be concluded that may recommended retain terms reduced peri-implant stresses occur denture dislodgment which lead increased bone resorption around implants.
منابع مشابه
Clinical evaluation of mandibular implant overdentures via Locator implant attachment and Locator bar attachment
PURPOSE The aim of this study was to evaluate the clinical findings and patient satisfaction on implant overdenture designed with Locator implant attachment or Locator bar attachment in mandibular edentulous patients. MATERIALS AND METHODS Implant survival rate, marginal bone loss, probing depth, peri-implant inflammation, bleeding, plaque, calculus, complications, and satisfaction were evalu...
متن کاملStress analysis of mandibular implant overdenture with locator and bar/clip attachment: Comparative study with differences in the denture base length
PURPOSE The design of the attachment must provide an optimum stress distribution around the implant. In this study, for implant overdentures with a bar/clip attachment or a locator attachment, the stress transmitted to the implant in accordance with the change in the denture base length and the vertical pressure was measured and analyzed. MATERIALS AND METHODS Test model was created with epox...
متن کاملComparative evaluation of peri-implant tissues in patients wearing mandibular overdenture with different implant platforms
Background The poor hygiene of peri-implant tissues causes inflammation at tissue-implant interface, which may impair the rehabilitation success. The aim of this study was to evaluate the influence of external hexagon and Morse taper implants on peri-implant health in patients wearing mandibular overdentures for 1 year. Materials and Methods A total of 46 implants were evaluated, 28 external ...
متن کاملImplant Supported Milled Bar Mandibular Overdenture with Locator Attachments: Clinical Considerations and Laboratory Techniques
Mailing address: RETAL CLINC, P. O. BOX 126242, JEDDAH 21352, SAUDI ARABIA, E-mail: [email protected] Abstract Both fixed and removable implant-supported restorations successfully address problems associated with complete dentures in edentulous mandibles. Implant-supported overdentures are frequently the restoration of choice in complex restorative situations where facial support is needed or...
متن کاملMaximum dislodging forces of implant overdenture stud attachments.
PURPOSE The aim of this study was to compare the retention and stability of the Nobel Biocare standard ball (NBS), Nobel Biocare 2.25-mm-diameter ball (NB2), Zest Anchor (ZA), Zest Anchor Advanced Generation (ZAAG), Sterngold ERA orange (SEO), and Sterngold ERA white (SEW) attachments on an implant-retained overdenture model. MATERIALS AND METHODS The attachments were tested using 2 permanent...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Egyptian dental journal
سال: 2021
ISSN: ['0070-9484', '2090-2360']
DOI: https://doi.org/10.21608/edj.2021.52107.1383