People need durable shelters for living safely due to devastation caused by flooding in some areas, and it is not easy mitigate the frequency intensity of flooding. Therefore, this research, an industrialized building system (IBS) has been proposed as one best solutions. However, most existing IBSs were designed tested resisting a sudden horizontal impact. Furthermore, joints would likely be vulnerable failure when subjected There develop bolt-connected IBS that able withstand impact load. Thus, study aimed investigate performance steel-bolt-connected frames hydrodynamic force. Autodesk computational fluid dynamic (CFD) simulation was used optimizing laboratory experiment. A 1:5-scale frame dam-break test using 1 m, 2 3 m reservoir water levels. The results showed bolt connections very effective robust frame. They also restricted damages from spreading other structural components energy dissipation. main findings are crucial improving current method construction.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance-Based Plastic Design of Moment Frame-Steel Plate Shear Wall as a Dual System

Steel Plate Shear Wall (SPSW) is an emerging seismic load-resistant system that, compared to other systems, enjoys the advantages of stable ductile behavior, fewer detailing requirements, rapid constructability, and economy. American seismic provisions decree that a SPSW should be designed as a moment frame with a web infill plate. Specifically, in case of buildings taller than 160 ft, it decre...

متن کامل

Reliability Analysis of Steel Building Frame Under Earthquake Forces

A simplified fragility analysis of steel building frame is presented which can be used for preliminary estimate of its probability of failure. The risk analysis procedure uses the format of probabilistic Risk Analysis (PRA) and considers band limited white noise at the bed rock as the seismic input. The steel building frame is modeled as a 2D frame and Pushover analysis is then carried out to o...

متن کامل

OPTIMUM PERFORMANCE-BASED DESIGN OF CONCENTRICALLY BRACED STEEL FRAMES SUBJECTED TO NEAR-FAULT GROUND MOTION EXCITATIONS

This paper presents a practical methodology for optimization of concentrically braced steel frames subjected to forward directivity near-fault ground motions, based on the concept of uniform deformation theory. This is performed by gradually shifting inefficient material from strong parts of the structure to the weak areas until a state of uniform deformation is achieved. In this regard, to ove...

متن کامل

Effect of Tethers Tension Force in the Behavior of a Tension Leg Platform Subjected to Hydrodynamic Force

The tension leg platform (TLP) is one of the compliant structures which are generally used for deep water oil exploration. With respect to the horizontal degrees of freedom, it behaves like a floating structure moored by vertical tethers which are pretension due to the excess buoyancy of the platform, whereas with respect to the vertical degrees of freedom, it is stiff and resembles a fixed str...

متن کامل