PD35-08 SINGLE-PORT MINI-PFANNENSTIEL ROBOTIC PYELOPLASTY: AN ALTERNATIVE TO MULTI-PORT ROBOTIC

نویسندگان

چکیده

You have accessJournal of UrologyTrauma/Reconstruction/Diversion: Ureter (including Pyeloplasty) and Bladder Reconstruction fistula), Augmentation, Substitution, Diversion I (PD35)1 Sep 2021PD35-08 SINGLE-PORT MINI-PFANNENSTIEL ROBOTIC PYELOPLASTY: AN ALTERNATIVE TO MULTI-PORT Alp Tuna Beksac, Clark Wilson, Mahmoud Abou Zeinab, Sij Hemal, Louis Lenfant, Zeyad Schwen, Soodong Kim, Alireza Aminsharifi, Jihad Kaouk BeksacAlp Beksac More articles by this author , WilsonClark Wilson ZeinabMahmoud Zeinab HemalSij Hemal LenfantLouis Lenfant SchwenZeyad Schwen KimSoodong Kim AminsharifiAlireza Aminsharifi KaoukJihad View All Author Informationhttps://doi.org/10.1097/JU.0000000000002039.08AboutPDF ToolsAdd to favoritesDownload CitationsTrack CitationsPermissionsReprints ShareFacebookLinked InTwitterEmail Abstract INTRODUCTION AND OBJECTIVE: The purpose built single port (SP) surgical platform offers a less invasive approach perform pyeloplasty, which can potentially facilitate early discharge decrease opioid use after surgery. We sought assess the efficacy SP robotic pyeloplasty using modified mini-pfannenstiel incision. METHODS: From institution series, 24 patients who underwent primary dismembered between February 2018 September 2020 were analyzed. Twelve standard MP 12 via 3 cm pfannenstiel access. association baseline perioperative characteristics analyzed using, chi-square, Fisher’s exact, Mann Whitney U t-tests. RESULTS: Baseline comparable except for higher body mass index in group (27.7 vs. 23.1 kg/m2, p=0.045). Operative time (p=0.146), estimated blood loss (p=0.150) comparable. No complications seen either group. had drain placed, whereas was omitted Length stay shorter (11.4 42.6 hours, p<0.001). lower usage hospital (3.2 44.3 morphine milligram equivalent, p<0.001) rate prescription (18.2% 91.7% CONCLUSIONS: Single-port through access eliminates all additional ports allows similar operative times outcomes when compared multi-port approach. In our series significantly mean length received opiates. Larger studies with long term follow up are needed confirm these findings evaluate long-term outcomes. Source Funding: None © 2021 American Urological Association Education Research, Inc.FiguresReferencesRelatedDetails Volume 206Issue Supplement 3September 2021Page: e591-e592 Advertisement Copyright & Permissions© Inc.MetricsAuthor Information Expand Loading ...

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Robotic Single-Port Hernia Surgery

BACKGROUND AND OBJECTIVES Since the introduction of single-incision laparoscopic surgery in 2009, an increasing number of surgical procedures including hernia repair are being performed using this technique. However, its large-scale adoption awaits results of prospective randomized controlled studies confirming its potential benefits. Parallel with single-port surgery development, the issue of ...

متن کامل

Current status of robotic single-port surgery

Robotic-assisted laparoscopic surgery in urology is an ever progressing field, and boundaries are constantly broken with the aid of new technology. Advancements in instrumentation have given birth to the era of robotic laparoendoscopic single-site technique (R-LESS). R-LESS however, has not gained widespread acceptance due to technical hurdles such as adequate triangulation, robotic arm clashin...

متن کامل

Initial experience with single-port robotic hysterectomy

OBJECTIVE This article presents the first series of robotic single-port hysterectomy cases performed at a hospital in Brazil. METHODS From November 2014 to October 2016, 11 patients were indicated to undergo, and nine of them were submitted to single-port hysterectomy using da Vinci Single-Site® platform. However, in two patients, due to multiple previous abdominal surgeries, large uterine vo...

متن کامل

New Maneuver in Robotic Single-Port Cholecystectomy.

The need to integrate aspects of functional, psychosocial and cosmetic impairment into medical care is increasingly accepted among the physicians and the patients. For these reasons, single-port robotic surgery emerges as the most advanced approach using the technology. In this study, authors used a new robotic dissector with monopolar electrocautery feature in order to determine the device's s...

متن کامل

Multi-port Neuroendoscope for Robotic Intraventricular Procedures

About 20% of brain surgeries are performed to remove lesions located inside or adjacent to the brain’s ventricles [1]. Using endoscopes, neurosurgeons can navigate their instruments through the ventricles to reach these lesions with less damage to healthy brain tissue than occurs in open surgery. Current endoscopes, however, are restricted by several factors. First, the tools emerge parallel to...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: The Journal of Urology

سال: 2021

ISSN: ['0022-5347', '1527-3792']

DOI: https://doi.org/10.1097/ju.0000000000002039.08