Parallel resonance type fault current limiting circuit breaker
نویسندگان
چکیده
منابع مشابه
Of a High Current Hvdc Circuit Breaker with Fast Fault Clearing Capability
Recent yea rs have seen r a p i d growth i n d i r e c t c u r r e n t t ransmiss ion. Th is growth increases the need and scope o f a p p l i c a t i o n f o r a h i g h vo l tage d i r e c t c u r r e n t c i r c u i t breaker . S i g n i f i c a n t improvements have been made i n a p r e v i o u s l y developed 500 kV, 2000A HVdc c i r c u i t breaker . These improvements have increased t h...
متن کاملZAMBEZI: a parallel pattern parallel fault sequential circuit fault simulator
Sequential circuit fault simulators use the multiple bits in a computer data word to accelerate simulation. We introduce, and implement, a new sequential circuit fault simulator, a parallel pattern parallel fault simulator, ZAMBEZI, which simultaneously simulates multiple faults with multiple vectors in one data word. ZAMBEZI is developed by enhancing the control ow of existing parallel pattern...
متن کاملA Model-Based Fault Detection Framework for Vacuum Circuit Breaker by Trip Coil Analysis
Vacuum circuit breaker becomes more and more complicated, integrated, high-speed and intellectualized. To insure vacuum circuit breaker in its good conditions, the function of fault diagnosis gets more important than before in the process of repairing. This paper is addressed a modelbased fault detection framework for vacuum circuit breaker by trip coil analysis. At first, the electromagnetic m...
متن کاملFault Diagnosis Method of HV Circuit Breaker Based on Wavelets Neural Network
Fault diagnosis of HV circuit break has been investigated extensively as an important device in the field of power system. In view of the shortcoming of the traditional neural network, such as the slow convergence rate and the local minimum easy to form, fault diagnosis method of HV circuit breaker is proposed to remedy the defects of traditional neural network based on wavelets neural. This me...
متن کاملInvestigation of Circuit Breaker Dielectric Performance
The violent event of a short-circuit leads to short-term exposure of circuit breaker components to extremely high current, causing thermal degradation, vaporization and deformation of some components and the deposition of surface contaminants. After short-circuit, the leakage current carried by the breaker, when voltage is applied, increases dramatically but must remain below a certain threshol...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: High Voltage
سال: 2020
ISSN: 2397-7264,2397-7264
DOI: 10.1049/hve.2019.0146