[P238] Dosimetric evaluation of deformable image registration error using 4DCT-MRI datasets
نویسندگان
چکیده
منابع مشابه
A Study on Robustness of Various Deformable Image Registration Algorithms on Image Reconstruction Using 4DCT Thoracic Images
Background: Medical image interpolation is recently introduced as a helpful tool to obtain further information via initial available images taken by tomography systems. To do this, deformable image registration algorithms are mainly utilized to perform image interpolation using tomography images.Materials and Methods: In this work, 4DCT thoracic images of five real patients provided by DI...
متن کاملEvaluation of deformable image registration in HDR gynecological brachytherapy
Introduction: In brachytherapy, as in external radiotherapy, image-guidance plays an important role. For GYN treatments it is standard to acquire at least CT images and preferably MR images prior to each treatment and to calculate the dose of the day on each set of images. Then, the dose to the target and to the organs at risk (OAR) is calculated with worst case scenario from I...
متن کاملa study on robustness of various deformable image registration algorithms on image reconstruction using 4dct thoracic images
background: medical image interpolation is recently introduced as a helpful tool to obtain further information via initial available images taken by tomography systems. this information may be useful for better diagnosis of possible lesions or better tumor delineation at radiation treatment. to do this, deformable image registration algorithms are mainly utilized to perform image interpolation ...
متن کاملEvaluation of Deformable Image Registration
Deformable image registration (DIR) is a type of registration that calculates a deformable vector field (DVF) between two image data sets and permits contour and dose propagation. However the calculation of a DVF is considered an ill-posed problem, as there is no exact solution to a deformation problem, therefore all DVFs calculated contain errors. As a result it is important to evaluate and as...
متن کاملEvaluation of deformable registration of patient lung 4DCT with subanatomical region segmentations.
Deformable registration is needed for a variety of tasks in establishing the voxel correspondence between respiratory phases. Most registration algorithms assume or imply that the deformation field is smooth and continuous everywhere. However, the lungs are contained within closed invaginated sacs called pleurae and are allowed to slide almost independently along the chest wall. This sliding mo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Physica Medica
سال: 2018
ISSN: 1120-1797
DOI: 10.1016/j.ejmp.2018.06.522