[P056] Dose distribution from computed tomograghy in anthropomorphic phantom using gafchromic XR-QA2 AND TLD100H
نویسندگان
چکیده
منابع مشابه
Gafchromic XR‐QA2 film as a complementary dosimeter for hand‐monitoring in CTF‐guided biopsies
Computed tomography fluoroscopy (CTF) is a useful imaging technique to guide biopsies, particularly lung biopsies, but it also has the potential for very high hand exposures, despite use of quick-check method and needle holders whenever feasible. Therefore, reliable monitoring is crucial to ensure the safe use of CTF. This is a challenge, because ring dosimeters monitor exposure only at the bas...
متن کاملAsymmetric breast dose in coronary angiography
The purpose of this study was to demonstrate asymmetric radiation dose distribution to the breasts in coronary angiography. Gafchromic XR-QA2 film was used as an area dosimeter to capture the asymmetric dose distribution to the breasts at various tissue depths in an anthropomorphic phantom. A selection of tube angulations were used under a controlled experiment and during a mock coronary angiog...
متن کاملUltraviolet exposure of Gafchromic XR‐RV3 and XR‐SP2 films
Gafchromic film has been used for X-ray dose measurement in diagnostic examinations. Their use has been initiated for three-dimensional X-ray dose measurement by using the high-resolution characteristics of Gafchromic films in computed tomography. However, it is necessary to solve the problem of nonuniform thickness in the active layers of Gafchromic films. A double exposure technique using X-r...
متن کاملDetermining rectal dose through cervix cancer radiotherapy by 9 MV photon beam using TLD and XR type T GAFCHROMIC® Film
Background: The goals of the present research were to investigate the rectal dose during four chosen techniques of cervical cancer radiotherapy and to examine how accurately the treatment planning represents dose measurements, and it’s practicality for routine use as well as, to determine the homogeneity of dose in tumor volume. Materials and Methods: The study was carried out using a Nepton 10...
متن کاملDose distribution and dosimetry parameters calculation of MED3633 palladium-103 source in water phantom using MCNP
Background: Palladium-103 (103Pd) is a brachytherapy source for cancer treatment. The Monte Carlo codes are usually applied for dose distribution and effect of shieldings. Monte Carlo calculation of dose distribution in water phantom due to a MED3633 103Pd source is presented in this work. Materials and Methods: The dose distribution around the 103Pd Model MED3633 located in the center of 30×...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Physica Medica
سال: 2018
ISSN: 1120-1797
DOI: 10.1016/j.ejmp.2018.06.379