منابع مشابه
Simple oxygen-failure safety device.
Recent correspondence in the British Medical Journall-4 has discussed the need for oxygen-failure devices and the philosophy of their design, so we shall not repeat this discussion here. Briefly, however, we think that very occasional oxygen failures are inevitable, during both anaesthesia and artificial ventilation with oxygen. Because the danger is so remote any safety device that is to gain ...
متن کاملAn unusual failure of an oxygen fail-safe device.
OXYGEN FAIL-SAFE SYSTEMS for anaesthetic gas machines have been advocated as standard safety features. 1-4 They are designed to prevent delivery of hypoxic gas mixtures in the event of an interruption or exhaustion of O~ pipeline or tank sources. In such a circumstance the fail-safe device causes all gas flow to cease, so alerting the operator of the apparatus to the problem. Some types of gas ...
متن کاملFailure mechanisms of discrete protection device subjected to repetitive electrostatic discharges (ESD)
High reliability electronic devices need to sustain thousand of Electrostatic Discharge (ESD) stresses during their lifetime. In this paper, it is demonstrated that repetitive ESD stresses on a protection device such as a bidirectional diode induce progressive defects into the silicon bulk. With “Sirtl etch” failure analysis technique, the defects could be localized quite precisely at the perip...
متن کاملDevice Data Protection in Mobile Healthcare Applications
The rapid growth in mobile technology makes the delivery of healthcare data and services on mobile phones a reality. However, the healthcare data is very sensitive and has to be protected against unauthorized access. While most of the development work on security of mobile healthcare today focuses on the data encryption and secure authentication in remote servers, protection of data on the mobi...
متن کاملSensitivity Assessment of Lightning Protection Device Aging Effect on Distribution Substation Insulation
Insufficient electrical endurance of equipment and insulation failure against overvoltage is one of the most effective reasons for failure the power line. Lightening, switching or other disruptive parameters can cause line outage or distribution substation failure. There are different devices used to improve the safety, reliability, and power quality of the system. Surge arresters are one of t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: British Journal of Anaesthesia
سال: 1981
ISSN: 0007-0912
DOI: 10.1093/bja/53.7.780