Objectives: A modified Blalock-Taussig (mBT) shunt procedure is a common palliative surgery used to treat infants and children with cyanotic congenital heart disease (CCHD). This study aimed report the outcomes of undergoing mBT procedures in Oman. In addition, risk factors associated early mortality, inter-stage mortality reintervention were assessed. Methods: retrospective cohort was conducted from January 2016 December 2018 at National Heart Centre, Muscat, All paediatric patients CCHD as primary during this period included. Data retrieved electronic hospital records. Kaplan-Meier survival curves describe overall survival. Results: total 50 included study. The in-hospital rates 10% 6.7%, respectively. Preoperative mechanical ventilation (odds ratio [OR]: 3.00, 95% confidence interval [CI]: 1.98–4.76; P = 0.007) cardiopulmonary bypass (OR: 4.09, CI: 2.44–6.85; 0.002) significant for mortality. In-hospital surgical 12% 13.3%, Following procedure, median time second-stage 15.5 months (range: 5.0–34.0 months). Conclusion: findings support those reported international research regarding risks surgeries. particular, preoperative mortality.
 Keywords: Pediatrics; Diseases, congenital; Cardiovascular Surgical Procedures; Modified Procedure; Patient Outcome Assessment; Hospital Mortality; Risk Factors;
منابع مشابه
False aneurysm following modified Blalock-Taussig shunt.
A nine month old infant with life threatening tracheal compression due to a Blalock-Taussig shunt aneurysm is described. Successful surgical management is discussed.
متن کاملPseudoaneurysm following modified Blalock Taussig shunt.
The modified Blalock-Taussig (BT) shunt is a common palliative procedure for congenital cyanotic heart disease (CHD) with diminished pulmonary blood flow(1). In developing countries, definitive surgery usually gets delayed due to limited resources and expertise(2). Children with cyanotic CHD and BT shunt often present to the pediatrician resulting in some of the complications of BT shunt being ...
متن کاملBlalock - Taussig shunt . modified ( polytetrafluoroethylene ) Balloon dilatation of a stenosed
A 17 month old girl with tricuspid atresia, ventricular septal defect, subvalvar and valvar pulmonary stenosis, and increasing cyanosis had angiographic evidence ofproximal stenosis of a right modified (5 mm diameter) Blalock-Taussig shunt. She underwent palliative balloon angioplasty with a 6 mm Schneider balloon catheter. Successful dilatation was achieved without complication. Four months la...
متن کاملBalloon dilatation of a stenosed modified (polytetrafluoroethylene) Blalock-Taussig shunt.
A 17 month old girl with tricuspid atresia, ventricular septal defect, subvalvar and valvar pulmonary stenosis, and increasing cyanosis had angiographic evidence of proximal stenosis of a right modified (5 mm diameter) Blalock-Taussig shunt. She underwent palliative balloon angioplasty with a 6 mm Schneider balloon catheter. Successful dilatation was achieved without complication. Four months l...
متن کاملRisk Factors for Thrombosis, Overshunting and Death in Infants after Modified Blalock-Taussig Shunt.
BACKGROUND The Modified Blalock-Taussig shunt procedure can provide increased flow of blood to the lungs for babies born with certain congenital heart defects. We evaluated 44 subjects under 2 years of age who had a Modified Blalock-Taussig shunt (MBTS) procedure performed from 2009-2013, to investigate risk factors for thrombosis, overshunting and death. METHODS The study subjects included i...