Out-of-field dosimetry measurements for a helical tomotherapy system
نویسندگان
چکیده
منابع مشابه
Out‐of‐field dosimetry measurements for a helical tomotherapy system†
Helical tomotherapy is a rotational delivery technique that uses intensity-modulated fan beams to deliver highly conformal intensity-modulated radiation therapy (IMRT). The beam-on time needed to deliver a given prescribed dose can be up to 15 times longer than that needed using conventional treatment delivery. As such, there is concern that this delivery technique has the potential to increase...
متن کاملClinical helical tomotherapy commissioning dosimetry.
Helical tomotherapy presented many unique dosimetric challenges and solutions during the initial commissioning process, and some of them are presented. The dose calculation algorithm is convolution/superposition based. This requires that the energy fluence spectrum and magnitude be quantified. The methodology for doing so is described. Aspects of the energy fluence characterization that are uni...
متن کاملProstate Helical Tomotherapy: A semi-empirical estimation of the scaling factor based on 2D approximating field
Background: In Helical Tomotherapy (HT), the scaling factor (SF) is the time in seconds that each leaf viewing a target would need to be open to deliver the prescribed dose. The SF is patient-specific and is used to calculate the rotational period of the gantry, and the total treatment time (TTT) of the HT. The SF is generally difficult to estimate. Currently, it takes about one hour t...
متن کاملCraniospinal irradiation using helical tomotherapy for central nervous system tumors
The aim of this study was to describe early and late toxicity, survival and local control in 45 patients with primary brain tumors treated with helical tomotherapy craniospinal irradiation (HT-CSI). From 2006 to 2014, 45 patients with central nervous system malignancies were treated with HT-CSI. The most common tumors were medulloblastoma in 20 patients, ependymoma in 10 patients, intracranial ...
متن کاملAssessment of a three‐dimensional (3D) water scanning system for beam commissioning and measurements on a helical tomotherapy unit
Beam scanning data collected on the tomotherapy linear accelerator using the TomoScanner water scanning system is primarily used to verify the golden beam profiles included in all Helical TomoTherapy treatment planning systems (TOMO TPSs). The user is not allowed to modify the beam profiles/parameters for beam modeling within the TOMO TPSs. The authors report the first feasibility study using t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Applied Clinical Medical Physics
سال: 2006
ISSN: 1526-9914
DOI: 10.1120/jacmp.v7i3.2212