Oscillation frequencies of tapered plant stems
نویسندگان
چکیده
منابع مشابه
Oscillation frequencies of tapered plant stems.
Free oscillations of upright plant stems, or in technical terms, slender tapered rods with one end free, can be described by considering the equilibrium between bending moments in the form of a differential equation with appropriate boundary conditions. For stems with apical loads, where the mass of the stem is negligible, Mathematica 4.0 returns solutions for tapering modes α = 0, 0.5, and 1. ...
متن کاملSecond-Generation Versus First-Generation Cementless Tapered Wedge Femoral Stems.
Clinical outcomes of a new second-generation proximally coated, tapered wedge cementless stem were compared with those of its predecessor regarding (1) all-cause implant survivorship; (2) objective and subjective outcomes; (3) complications; and (4) radiographic features. Patients who underwent a primary total hip arthroplasty with the second-generation stem (68 hips) were compared with those w...
متن کاملModular Femoral Tapered Revision Stems in Total Hip Arthroplasty
Background: Modular component options can assist the surgeon in addressing complex femoral reconstructions in total hip arthroplasty by allowing for customization of version control and proximal to distal sizing. We review the early clinical results of a single modular femoral revision system that offers 3 proximal body types, 5 distal stem geometries, and a wide range of offset, sizing and aux...
متن کاملInfluence of stem geometry on the stability of polished tapered cemented femoral stems.
Polished, tapered stems are now widely used for cemented total hip replacement and many such designs have been introduced. However, a change in stem geometry may have a profound influence on stability. Stems with a wide, rectangular proximal section may be more stable than those which are narrower proximally. We examined the influence of proximal geometry on stability by comparing the two-year ...
متن کاملDistal fixation of proximally coated tapered stems may predispose to a failure of osteointegration.
Despite excellent long-term results of proximally coated tapered wedge femoral stems in noncemented total hip arthroplasty, we have consistently observed a minority fail to achieve osteointegration. We retrospectively reviewed 320 consecutive total hip arthroplasties performed by a single surgeon using a single stem over a 4-year period. Clinical and radiographic parameters were analyzed for ri...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: American Journal of Botany
سال: 2002
ISSN: 0002-9122,1537-2197
DOI: 10.3732/ajb.89.1.1