Optimum drilled flange moment resisting connections for seismic regions
نویسندگان
چکیده
منابع مشابه
Seismic behavior of drilled beam section in moment connections
Abstract: Reduced Beam Section (RBS) and Drilled Beam Section (DBS) are seismic moment resistant frame connections, introduced after 1994 Northridge earthquake. RBS connection has been tested under cyclic loading and showed acceptable performance. In this paper, seismic behavior of Drilled Beam Section (DBS) connection is studied numerically using finite element method. A drilled beam section ...
متن کاملA COMPARATIVE STUDY OF OPTIMUM AND IRANIAN SEISMIC DESIGN FORCE DISTRIBUTIONS FOR STEEL MOMENT RESISTING BUILDINGS
In this study, constant-ductility optimization algorithm under a family of earthquake ground motions is utilized to achieve uniform damage distribution over the height of steel moment resisting frames (SMRFs). SMRF structures with stiffness-degrading hysteric behavior are modeled as single-bay generic frame in which the plastic hinge is confined only at the beam ends and the bottom of the first...
متن کاملASSESSMENT OF DUCTILITY REDUCTION FACTOR FOR OPTIMUM SEISMIC DESIGNED STEEL MOMENT-RESISTING FRAMES
In the present study, ten steel-moment resisting frames (SMRFs) having different numbers of stories ranging from 3 to 20 stories and fundamental periods of vibration ranging from 0.3 to 3.0 second were optimized subjected to a set of earthquake ground motions using the concept of uniform damage distribution along the height of the structures. Based on the step-by-step optimization algorithm dev...
متن کاملNumerical study of slotted web drilled flange moment frame connection
Beam connections with reduced drilled section and slotted web have been presented after the Northridge earthquake (1994). Their new geometrical shapes have been resulted in weakening of beams and subsequently the bette rperformance of connections in the earthquakes. In this research, the advantages of both connections, mentioned above, have been studied in the Slotted Web Drilled Flange (SWDF) ...
متن کاملMoment-resisting connections in glulam beams
This paper describes an experimental investigation into the use of steel bars bonded into glulam timber beams with epoxy resins in order to provide moment-resisting joints between glulam beams and steel supports. The objective of this research was to provide information about the bending and shear strength of such connections. Past research has investigated the use of steel rods epoxy bonded in...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Constructional Steel Research
سال: 2015
ISSN: 0143-974X
DOI: 10.1016/j.jcsr.2015.05.013